KinDR007 / VictronMPPT-ESPHOME

Victron Mppt charger ve.direct to esphome node
MIT License
297 stars 64 forks source link

Some values are not displayed Victron MPPT 150/45 and 100/20 #155

Closed DerKlotz74 closed 3 months ago

DerKlotz74 commented 5 months ago

Hello, I have the problem that some values are not supplied by the Victron. Please help. What is needed?

sensor:
  - platform: victron
    victron_id: victron150
    max_power_yesterday:
      name: "${device0} max power yesterday"
    max_power_today:
      name: "${device0} max power today"  
    panel_voltage:
      name: "${device0} panel voltage"
    panel_power:
      name: "${device0} panel power"
    battery_current:
      name: "${device0} panel current"
    load_current:
      name: "${device0} load current"
    battery_voltage:
      name: "${device0} battery voltage"
    min_battery_voltage:
      name: "${device0} min battery voltage" 
    max_battery_voltage:
      name: "${device0} max battery voltage" 
    number_of_charge_cycles:  
      name: "${device0} number of charge circles"
    number_of_full_discharges:
      name: "${device0} number of full discharges"
    amount_of_discharged_energy:
      name: "${device0} amount of discharged energy"
    amount_of_charged_energy:
      name: "${device0} amount of charged energy"  

Victron1 Victron2

DerKlotz74 commented 5 months ago

Have an ESP32

syssi commented 3 months ago

Please enable the debug output of the uart component and provide some logs.

uart:
  id: uart_0
  baud_rate: 19200
  tx_pin: ${tx_pin}
  rx_pin: ${rx_pin}
  debug:
    direction: BOTH
    dummy_receiver: false
    after:
      delimiter: "\n"
    sequence:
      - lambda: UARTDebug::log_string(direction, bytes);

I assume your Victron device doesn't provide the missing measurements above and you have to simply remove the sensors from the YAML to get rid of the useless sensors without measurements.

KinDR007 commented 3 months ago

Hi , sorry for delayed response. All values with N/A corespond for smartshunt or BVM these values are not available for MPPT's