KlementineJBS / USYD_PhD_ELN

This repository forms the electronic laboratory notebook (ELN)for Klementine Burrell-Sander's PhD's
2 stars 0 forks source link

Breaking Good SSP compounds 2022 - 8A #36

Closed KlementineJBS closed 1 year ago

KlementineJBS commented 1 year ago

image

KlementineJBS commented 1 year ago

LRMS

BG_8A.d.zip BG_8A.pdf

KlementineJBS commented 1 year ago

IR

BG_8A.pdf

KlementineJBS commented 1 year ago

Column 2

image

Cartridge | SNAP KP-Sil 25g Flowrate | 75 ml/min Solvent A | Dichloromethane Solvent B | 1-9-90 NH4OH-MeOH-DCM

BG_8A F6-24_1.zip BG_8A F25-27_1.zip BG_8A F28-34_1.zip BG_8A F35-42_1.zip

BG_8A 2nd column all fractions.pdf

Fractions 25-34 appear to be the cleanest, though uncertain what the minor peak at 3.92 represents.

KlementineJBS commented 1 year ago

22.11.22

Fractions 25-27 and 28-34 both still contained grease. Triturated to remove.

F25-27 - dissolved in MeCN and washed with spectroscopic grade hexane (5 x 2 mL). F28-34 - washed with spectroscopic grade hexane (5 x 1.5 mL).

NMR indicates that acetonitrile wash was more effective - grease is ~ 20% of that in the other sample.

8A 25-27 22-11-22_1.zip 8A 28-34 22-11-22_1.zip

BG_8A 22-11-22.pdf