Closed makelele closed 3 years ago
It looks like this ticket is a request for help (or similar). Many helpful people will not see your message here and you are unlikely to get a useful response. Instead, see the contact directions at: https://www.klipper3d.org/Contact.html
We use github to share the results of work done to improve Klipper. We don't use github for requests. (In particular, we don't use github for feature requests, to answer questions, nor to help diagnose problems with a printer.)
Please follow the directions at: https://www.klipper3d.org/Contact.html
This ticket will be automatically closed.
Best regards, ~ Your friendly GitIssueBot
PS: I'm just an automated script, not a human being.
Oh - the "internal error" is an area where Klipper could be improved. However, the root cause of your issue is a "heater not heating at expected rate" - you should reach out to the Klipper community if you need help with that.
-Kevin
ok, thank you.
@makelele, I am in a similar situation. Btw, I get the same reading if I don't plug the thermistor. So maybe I have a loose connection, or I am not plugging it on the correct pin on the board.
Did you manage to find the cause of your issue?
I confirm that my issue was due to a faulty connection.
I'm just gonna bring this up for @ddacunha and at @makelele https://github.com/KevinOConnor/klipper/issues/4054 These thermistors appear to be more accurate at printing temperatures using EPCOS 100K B57560G104F but you really need to test these.
@KevinOConnor does this want to be in the docs somewhere? I'll write it up and do a PR if it would be helpful. I've spent most of today finding ways to calibrate sensors and proper second guessing myself over sensor types.
Hello,
It looks like there hasn't been any recent updates on this Klipper github issue. If you created this issue and no longer consider it open, then please login to github and close the issue. Otherwise, if there is no further activity on this thread then it will be automatically closed in a few days.
Best regards,
~ Your friendly GitIssueBot
PS: I'm just an automated script, not a human being.
Hi, thank you so much for your hard work on Klipper. My issue is I have changed my thermistor and my heater cartridge and now I am having negative reading on my Sovol SV01. When I run PID_CALIBRATE I get an
Internal error on command:"PID_CALIBRATE"
klippy.logMy thermistor is 100k HT-NTC B3950 and I've been trying to add it but I can't. I'm getting -75 (negative) on my nozzle temperature. I attached the log.