Closed deviantintegral closed 3 months ago
The devices in this PR don't seem to actually ever send a battery alarm. I've only ever seen them report "normal" in z2m. I've been running a sniffer for 24 hours and zbee_zcl_general.power_config.attr_id > 0x0021 shows no results. If I'm reading https://github.com/Koenkk/zigbee-herdsman/blob/73162478f5e5c3d9058bfada27dfff52b9d2c612/src/zspec/zcl/definition/cluster.ts#L71 right, if reported it should be reported with attribute ID 0x3E.
zbee_zcl_general.power_config.attr_id > 0x0021
0x3E
Also, I've never had this value flip before a battery dies, so I don't think it is just waiting for a failure state to send.
Thanks!
The devices in this PR don't seem to actually ever send a battery alarm. I've only ever seen them report "normal" in z2m. I've been running a sniffer for 24 hours and
zbee_zcl_general.power_config.attr_id > 0x0021
shows no results. If I'm reading https://github.com/Koenkk/zigbee-herdsman/blob/73162478f5e5c3d9058bfada27dfff52b9d2c612/src/zspec/zcl/definition/cluster.ts#L71 right, if reported it should be reported with attribute ID0x3E
.Also, I've never had this value flip before a battery dies, so I don't think it is just waiting for a failure state to send.