Could you provide the data/database.db entry of your device detecteed as TS011F_wall_outlet?
{"id":13,"type":"Router","ieeeAddr":"0xa4c138ec2fdf815b","nwkAddr":13161,"manufId":4417,"manufName":"_TZ3000_b28wrpvx","powerSource":"Mains (single phase)","modelId":"TS011F","epList":[1,242],"endpoints":{"1":{"profId":260,"epId":1,"devId":266,"inClusterList":[3,4,5,6,1794,2820,57344,57345,0],"outClusterList":[25,10],"clusters":{"genBasic":{"attributes":{"65503":":zR,\u0003","65506":54,"65508":0,"65534":0,"modelId":"TS011F","manufacturerName":"_TZ3000_b28wrpvx","powerSource":1,"zclVersion":3,"appVersion":192,"stackVersion":0,"hwVersion":1,"dateCode":""}},"haElectricalMeasurement":{"attributes":{"acCurrentDivisor":1000,"acCurrentMultiplier":1,"rmsVoltage":218,"rmsCurrent":0,"activePower":0}},"seMetering":{"attributes":{"divisor":100,"multiplier":1,"currentSummDelivered":[0,27612]}},"genOnOff":{"attributes":{"32768":0,"onOff":1,"onTime":0,"offWaitTime":0,"tuyaBacklightMode":1,"moesStartUpOnOff":2,"tuyaBacklightSwitch":1}},"manuSpecificTuya_3":{"attributes":{"53248":1,"53249":0,"53250":2802818,"53251":122,"53252":11118,"53253":1284,"powerOnBehavior":2,"switchType":0}}},"binds":[{"cluster":6,"type":"endpoint","deviceIeeeAddress":"0x00124b0024cbdc43","endpointID":1},{"cluster":2820,"type":"endpoint","deviceIeeeAddress":"0x00124b0024cbdc43","endpointID":1},{"cluster":1794,"type":"endpoint","deviceIeeeAddress":"0x00124b0024cbdc43","endpointID":1}],"configuredReportings":[{"cluster":2820,"attrId":1285,"minRepIntval":5,"maxRepIntval":3600,"repChange":5,"manufacturerCode":null},{"cluster":2820,"attrId":1288,"minRepIntval":5,"maxRepIntval":3600,"repChange":50,"manufacturerCode":null},{"cluster":2820,"attrId":1291,"minRepIntval":5,"maxRepIntval":3600,"repChange":10,"manufacturerCode":null},{"cluster":1794,"attrId":0,"minRepIntval":5,"maxRepIntval":3600,"repChange":[1,1],"manufacturerCode":null}],"meta":{}},"242":{"profId":41440,"epId":242,"devId":97,"inClusterList":[],"outClusterList":[33],"clusters":{},"binds":[],"configuredReportings":[],"meta":{}}},"appVersion":192,"stackVersion":0,"hwVersion":1,"dateCode":"","zclVersion":3,"interviewCompleted":true,"meta":{"configured":1310285083},"lastSeen":1705066106835,"defaultSendRequestWhen":"immediate"}
_TZ3000_b28wrpvx
should be detected as TS011F_plug_1
, I need the data/database.db entries of the ones detected as TS011F_wall_outlet
Sorry, I read wrong. Here you have the first one:
{"id":27,"type":"Router","ieeeAddr":"0xa4c138829a350251","nwkAddr":41820,"manufId":4417,"manufName":"_TZ3000_o1jzcxou","powerSource":"Mains (single phase)","modelId":"TS011F","epList":[1,242],"endpoints":{"1":{"profId":260,"epId":1,"devId":266,"inClusterList":[3,4,5,6,57344,57345,0],"outClusterList":[25,10],"clusters":{"genBasic":{"attributes":{"stackVersion":0,"dateCode":""}},"genOnOff":{"attributes":{"32768":0,"onOff":1,"onTime":0,"offWaitTime":0,"tuyaBacklightMode":1,"moesStartUpOnOff":1,"tuyaBacklightSwitch":1}},"manuSpecificTuya_3":{"attributes":{"powerOnBehavior":1,"switchType":0}}},"binds":[],"configuredReportings":[],"meta":{}},"242":{"profId":41440,"epId":242,"devId":97,"inClusterList":[],"outClusterList":[33],"clusters":{},"binds":[],"configuredReportings":[],"meta":{}}},"appVersion":67,"stackVersion":0,"hwVersion":1,"dateCode":"","zclVersion":3,"interviewCompleted":true,"meta":{},"lastSeen":1705254198729,"defaultSendRequestWhen":"immediate"}
And the other one:
{"id":28,"type":"Router","ieeeAddr":"0xa4c138223600c41f","nwkAddr":30302,"manufId":4417,"manufName":"_TZ3000_o1jzcxou","powerSource":"Mains (single phase)","modelId":"TS011F","epList":[1,242],"endpoints":{"1":{"profId":260,"epId":1,"devId":266,"inClusterList":[3,4,5,6,57344,57345,0],"outClusterList":[25,10],"clusters":{"genBasic":{"attributes":{"modelId":"TS011F","manufacturerName":"_TZ3000_o1jzcxou","powerSource":1,"zclVersion":3,"appVersion":67,"stackVersion":0,"hwVersion":1,"dateCode":""}},"genOnOff":{"attributes":{"32768":0,"onOff":1,"onTime":0,"offWaitTime":0,"tuyaBacklightMode":1,"moesStartUpOnOff":1,"tuyaBacklightSwitch":1}},"manuSpecificTuya_3":{"attributes":{"powerOnBehavior":1,"switchType":0}}},"binds":[],"configuredReportings":[],"meta":{}},"242":{"profId":41440,"epId":242,"devId":97,"inClusterList":[],"outClusterList":[33],"clusters":{},"binds":[],"configuredReportings":[],"meta":{}}},"appVersion":67,"stackVersion":0,"hwVersion":1,"dateCode":"","zclVersion":3,"interviewCompleted":true,"meta":{},"lastSeen":1705254199107,"defaultSendRequestWhen":"immediate"}
Fixed!
Changes will be available in the dev branch in a few hours from now.
zigbee_herdsman_converters_version18.42.0 - Zigbee Model TS011F Zigbee Manufacturer _TZ3000_o1jzcxou
After adding the device status is permanent offline But turning it on and off works stably. When connecting any electrical device, power is sold correctly, but all sensors on the outlet are in Null or not available
Same here. Everything works well except I don't any metering data out of this socket.
Zigbee Model TS011F Zigbee Manufacturer _TZ3000_o1jzcxou
What happened?
Hello, In July 2023 I purchased a BSEED wall socket. When connected to Zigbee2mqtt it was recognized as "TS011F_plug_1" and exposed consumption and power. I use it to control the consumption of a refrigerator in Home Assistant. Recently and because of the good results it has given me, I have bought two more plugs from the same brand, but this time when I linked it they appear as "TS011F_wall_outlet" but it can only be controlled like a switch. My intention was to use these plugs to control the consumption of a washing machine and a dryer.
What did you expect to happen?
I hope to use this device to control electrical consumption
How to reproduce it (minimal and precise)
No response