Open Fitrog opened 8 months ago
Having the same issue,would really like to set switch_type setting.
const tuya = require('zigbee-herdsman-converters/lib/tuya');
const {deviceEndpoints, identify, onOff, electricityMeter} = require('zigbee-herdsman-converters/lib/modernExtend');
const definition = {
zigbeeModel: ['TS0004'],
model: 'TS0004',
vendor: '_TZ3000_mmkbptmx',
description: 'Automatically generated definition',
extend: [tuya.modernExtend.tuyaOnOff({switchType: true, endpoints: ['l1', 'l2', 'l3', 'l4']})],
endpoint: (device) => {
return {'l1': 1, 'l2': 2, 'l3': 3, 'l4': 4};
},
meta: {"multiEndpoint":true},
configure: async (device, coordinatorEndpoint) => {
await tuya.configureMagicPacket(device, coordinatorEndpoint);
await reporting.bind(device.getEndpoint(1), coordinatorEndpoint, ['genOnOff']);
await reporting.bind(device.getEndpoint(2), coordinatorEndpoint, ['genOnOff']);
await reporting.bind(device.getEndpoint(3), coordinatorEndpoint, ['genOnOff']);
await reporting.bind(device.getEndpoint(4), coordinatorEndpoint, ['genOnOff']);
},
};
module.exports = definition;
here is the external definition i used to make the switch type work.
Link
https://aliexpress.ru/item/1005005960005800.html?spm=a2g0o.order_list.order_list_main.9.21efa396093tVs&gatewayAdapt=glo2rus&sku_id=12000035050899856
Database entry
{"id":1,"type":"Coordinator","ieeeAddr":"0x00124b00258d56b8","nwkAddr":0,"manufId":0,"epList":[242,47,13,12,110,11,10,8,6,5,4,3,2,1],"endpoints":{"1":{"profId":260,"epId":1,"devId":5,"inClusterList":[],"outClusterList":[],"clusters":{},"binds":[],"configuredReportings":[],"meta":{}},"2":{"profId":257,"epId":2,"devId":5,"inClusterList":[],"outClusterList":[],"clusters":{},"binds":[],"configuredReportings":[],"meta":{}},"3":{"profId":260,"epId":3,"devId":5,"inClusterList":[],"outClusterList":[],"clusters":{},"binds":[],"configuredReportings":[],"meta":{}},"4":{"profId":263,"epId":4,"devId":5,"inClusterList":[],"outClusterList":[],"clusters":{},"binds":[],"configuredReportings":[],"meta":{}},"5":{"profId":264,"epId":5,"devId":5,"inClusterList":[],"outClusterList":[],"clusters":{},"binds":[],"configuredReportings":[],"meta":{}},"6":{"profId":265,"epId":6,"devId":5,"inClusterList":[],"outClusterList":[],"clusters":{},"binds":[],"configuredReportings":[],"meta":{}},"8":{"profId":260,"epId":8,"devId":5,"inClusterList":[],"outClusterList":[],"clusters":{},"binds":[],"configuredReportings":[],"meta":{}},"10":{"profId":260,"epId":10,"devId":5,"inClusterList":[],"outClusterList":[],"clusters":{},"binds":[],"configuredReportings":[],"meta":{}},"11":{"profId":260,"epId":11,"devId":1024,"inClusterList":[1281,10],"outClusterList":[1280,1282],"clusters":{},"binds":[],"configuredReportings":[],"meta":{}},"12":{"profId":49246,"epId":12,"devId":5,"inClusterList":[],"outClusterList":[],"clusters":{},"binds":[],"configuredReportings":[],"meta":{}},"13":{"profId":260,"epId":13,"devId":5,"inClusterList":[25],"outClusterList":[],"clusters":{},"binds":[],"configuredReportings":[],"meta":{}},"47":{"profId":260,"epId":47,"devId":5,"inClusterList":[],"outClusterList":[],"clusters":{},"binds":[],"configuredReportings":[],"meta":{}},"110":{"profId":260,"epId":110,"devId":5,"inClusterList":[],"outClusterList":[],"clusters":{},"binds":[],"configuredReportings":[],"meta":{}},"242":{"profId":41440,"epId":242,"devId":5,"inClusterList":[],"outClusterList":[],"clusters":{},"binds":[],"configuredReportings":[],"meta":{}}},"interviewCompleted":true,"meta":{},"lastSeen":null,"defaultSendRequestWhen":"immediate"} {"id":2,"type":"Router","ieeeAddr":"0xa4c138951cec1ce7","nwkAddr":47671,"manufId":4417,"manufName":"_TZ3000_mmkbptmx","powerSource":"Mains (single phase)","modelId":"TS0004","epList":[1,2,3,4,242],"endpoints":{"1":{"profId":260,"epId":1,"devId":256,"inClusterList":[3,4,5,6,1794,2820,57344,57345,0],"outClusterList":[25,10],"clusters":{"genBasic":{"attributes":{"65503":"\f\u0000\u0000\u0000\u0012\u0012\u0000\u0000\u0000\u0016","65506":56,"65508":0,"65534":0,"modelId":"TS0004","manufacturerName":"_TZ3000_mmkbptmx","powerSource":1,"zclVersion":3,"appVersion":72,"stackVersion":0,"hwVersion":1,"dateCode":""}},"manuSpecificBosch":{"attributes":{"53251":"AAAAAgAABAAABgAA"}},"genOnOff":{"attributes":{"onOff":0,"onTime":0,"offWaitTime":0,"moesStartUpOnOff":0}},"manuSpecificTuya_3":{"attributes":{"53248":0,"53249":0,"53250":0,"53251":0,"53252":0,"53253":0,"switchType":0}}},"binds":[{"cluster":6,"type":"endpoint","deviceIeeeAddress":"0x00124b00258d56b8","endpointID":242}],"configuredReportings":[],"meta":{}},"2":{"profId":260,"epId":2,"devId":256,"inClusterList":[4,5,6],"outClusterList":[],"clusters":{"genOnOff":{"attributes":{"onOff":0,"onTime":0,"offWaitTime":0}}},"binds":[{"cluster":6,"type":"endpoint","deviceIeeeAddress":"0x00124b00258d56b8","endpointID":242}],"configuredReportings":[],"meta":{}},"3":{"profId":260,"epId":3,"devId":256,"inClusterList":[4,5,6],"outClusterList":[],"clusters":{"genOnOff":{"attributes":{"onOff":0,"onTime":0,"offWaitTime":0}}},"binds":[{"cluster":6,"type":"endpoint","deviceIeeeAddress":"0x00124b00258d56b8","endpointID":242}],"configuredReportings":[],"meta":{}},"4":{"profId":260,"epId":4,"devId":256,"inClusterList":[4,5,6],"outClusterList":[],"clusters":{"genOnOff":{"attributes":{"onOff":0,"onTime":0,"offWaitTime":0}}},"binds":[{"cluster":6,"type":"endpoint","deviceIeeeAddress":"0x00124b00258d56b8","endpointID":242}],"configuredReportings":[],"meta":{}},"242":{"profId":41440,"epId":242,"devId":97,"inClusterList":[],"outClusterList":[33],"clusters":{},"binds":[],"configuredReportings":[],"meta":{}}},"appVersion":72,"stackVersion":0,"hwVersion":1,"dateCode":"","zclVersion":3,"interviewCompleted":true,"meta":{"configured":889996980},"lastSeen":1706061593792,"defaultSendRequestWhen":"immediate"}
Comments
Initially recognized as other device It is able to switch turn off, but It is not able to set switch_type setting, and power on behavior.
2gang switch was already opened, but mine is 4gang switch. https://github.com/Koenkk/zigbee2mqtt/issues/19670