Koenkk / zigbee2mqtt

Zigbee 🐝 to MQTT bridge 🌉, get rid of your proprietary Zigbee bridges 🔨
https://www.zigbee2mqtt.io
GNU General Public License v3.0
11.76k stars 1.64k forks source link

Paulmann 500.67 no longer supported #21105

Open derMicro opened 7 months ago

derMicro commented 7 months ago

What happened?

I have tried several times without success to integrate the Paulmann ZigBee remote control (500.67) which works but is listed as "Not supported" although this should be the case according to the documentation.

What did you expect to happen?

That it works or is supported :)

How to reproduce it (minimal and precise)

Permit Join Reset the remote control as described in the documentation here The remote control is listed under Devices. The interview is carried out and is successful The device receives the status "Not supported"

Force delete the device and repeat the whole process

image image

Zigbee2MQTT version

1.35.1-1

Adapter firmware version

20230507

Adapter

ZigStar UZG-01 FWV 0.2.0

Setup

Add-On HA 2024.1.5 on Intel Nuc

Debug log

Due to the amount of data in the MQTT, and the fact that many details of my IT are monitored via it, the log is shortened to the part with the remote control.

debug 2024-01-29 20:34:06: Received Zigbee message from '0x00158d0009a631ac', type 'commandColorLoopSet', cluster 'lightingColorCtrl', data '{"action":0,"direction":0,"starthue":0,"time":0,"updateflags":15}' from endpoint 1 with groupID 2 debug 2024-01-29 20:34:06: No converter available for '50067' with cluster 'lightingColorCtrl' and type 'commandColorLoopSet' and data '{"action":0,"direction":0,"starthue":0,"time":0,"updateflags":15}' info 2024-01-29 20:34:06: MQTT publish: topic 'zigbee2mqtt/0x00158d0009a631ac', payload '{"last_seen":"2024-01-29T20:34:06+01:00","linkquality":61}' debug 2024-01-29 20:34:06: Received Zigbee message from '0x00158d0009a631ac', type 'commandEnhancedMoveToHueAndSaturation', cluster 'lightingColorCtrl', data '{"enhancehue":54280,"saturation":254,"transtime":1}' from endpoint 1 with groupID 2 debug 2024-01-29 20:34:06: No converter available for '50067' with cluster 'lightingColorCtrl' and type 'commandEnhancedMoveToHueAndSaturation' and data '{"enhancehue":54280,"saturation":254,"transtime":1}' info 2024-01-29 20:34:06: MQTT publish: topic 'zigbee2mqtt/0x00158d0009a631ac', payload '{"last_seen":"2024-01-29T20:34:06+01:00","linkquality":83}' debug 2024-01-29 20:34:08: Received Zigbee message from 'GT_Light_Garden', type 'commandQueryNextImageRequest', cluster 'genOta', data '{"fieldControl":0,"fileVersion":1,"imageType":4353,"manufacturerCode":4632}' from endpoint 1 with groupID 0 info 2024-01-29 20:34:08: MQTT publish: topic 'zigbee2mqtt/GT_Light_Garden', payload '{"brightness":254,"last_seen":"2024-01-29T20:34:08+01:00","linkquality":83,"power_on_behavior":"off","state":"OFF"}' debug 2024-01-29 20:34:08: Device 'GT_Light_Garden' requested OTA debug 2024-01-29 20:34:08: Responded to OTA request of 'GT_Light_Garden' with 'NO_IMAGE_AVAILABLE' debug 2024-01-29 20:34:08: Received Zigbee message from '0x00158d0009a631ac', type 'commandColorLoopSet', cluster 'lightingColorCtrl', data '{"action":0,"direction":0,"starthue":0,"time":0,"updateflags":15}' from endpoint 1 with groupID 2 debug 2024-01-29 20:34:08: No converter available for '50067' with cluster 'lightingColorCtrl' and type 'commandColorLoopSet' and data '{"action":0,"direction":0,"starthue":0,"time":0,"updateflags":15}' info 2024-01-29 20:34:08: MQTT publish: topic 'zigbee2mqtt/0x00158d0009a631ac', payload '{"last_seen":"2024-01-29T20:34:08+01:00","linkquality":65}' debug 2024-01-29 20:34:08: Received Zigbee message from '0x00158d0009a631ac', type 'commandEnhancedMoveToHueAndSaturation', cluster 'lightingColorCtrl', data '{"enhancehue":20603,"saturation":254,"transtime":1}' from endpoint 1 with groupID 2 debug 2024-01-29 20:34:08: No converter available for '50067' with cluster 'lightingColorCtrl' and type 'commandEnhancedMoveToHueAndSaturation' and data '{"enhancehue":20603,"saturation":254,"transtime":1}' info 2024-01-29 20:34:08: MQTT publish: topic 'zigbee2mqtt/0x00158d0009a631ac', payload '{"last_seen":"2024-01-29T20:34:08+01:00","linkquality":61}' debug 2024-01-29 20:34:09: Received Zigbee message from '0x00158d0009a631ac', type 'commandColorLoopSet', cluster 'lightingColorCtrl', data '{"action":0,"direction":0,"starthue":0,"time":0,"updateflags":15}' from endpoint 1 with groupID 2 debug 2024-01-29 20:34:09: No converter available for '50067' with cluster 'lightingColorCtrl' and type 'commandColorLoopSet' and data '{"action":0,"direction":0,"starthue":0,"time":0,"updateflags":15}' info 2024-01-29 20:34:09: MQTT publish: topic 'zigbee2mqtt/0x00158d0009a631ac', payload '{"last_seen":"2024-01-29T20:34:09+01:00","linkquality":61}' debug 2024-01-29 20:34:09: Received Zigbee message from 'KU_Light_Lavabo', type 'commandQueryNextImageRequest', cluster 'genOta', data '{"fieldControl":0,"fileVersion":1,"imageType":4364,"manufacturerCode":4632}' from endpoint 1 with groupID 0 info 2024-01-29 20:34:09: MQTT publish: topic 'zigbee2mqtt/KU_Light_Lavabo', payload '{"brightness":102,"color_mode":"color_temp","color_temp":245,"color_temp_startup":370,"last_seen":"2024-01-29T20:34:09+01:00","linkquality":80,"power_on_behavior":"off","state":"OFF"}' debug 2024-01-29 20:34:09: Device 'KU_Light_Lavabo' requested OTA debug 2024-01-29 20:34:09: Received Zigbee message from '0x00158d0009a631ac', type 'commandEnhancedMoveToHueAndSaturation', cluster 'lightingColorCtrl', data '{"enhancehue":53098,"saturation":254,"transtime":1}' from endpoint 1 with groupID 2 debug 2024-01-29 20:34:09: No converter available for '50067' with cluster 'lightingColorCtrl' and type 'commandEnhancedMoveToHueAndSaturation' and data '{"enhancehue":53098,"saturation":254,"transtime":1}' info 2024-01-29 20:34:09: MQTT publish: topic 'zigbee2mqtt/0x00158d0009a631ac', payload '{"last_seen":"2024-01-29T20:34:09+01:00","linkquality":58}' debug 2024-01-29 20:34:09: Responded to OTA request of 'KU_Light_Lavabo' with 'NO_IMAGE_AVAILABLE' debug 2024-01-29 20:34:09: Received Zigbee message from '0x00158d0009a631ac', type 'commandColorLoopSet', cluster 'lightingColorCtrl', data '{"action":0,"direction":0,"starthue":0,"time":0,"updateflags":15}' from endpoint 1 with groupID 2 debug 2024-01-29 20:34:09: No converter available for '50067' with cluster 'lightingColorCtrl' and type 'commandColorLoopSet' and data '{"action":0,"direction":0,"starthue":0,"time":0,"updateflags":15}' info 2024-01-29 20:34:09: MQTT publish: topic 'zigbee2mqtt/0x00158d0009a631ac', payload '{"last_seen":"2024-01-29T20:34:09+01:00","linkquality":65}' debug 2024-01-29 20:34:09: Received Zigbee message from '0x00158d0009a631ac', type 'commandEnhancedMoveToHueAndSaturation', cluster 'lightingColorCtrl', data '{"enhancehue":457,"saturation":254,"transtime":1}' from endpoint 1 with groupID 2 debug 2024-01-29 20:34:09: No converter available for '50067' with cluster 'lightingColorCtrl' and type 'commandEnhancedMoveToHueAndSaturation' and data '{"enhancehue":457,"saturation":254,"transtime":1}' info 2024-01-29 20:34:09: MQTT publish: topic 'zigbee2mqtt/0x00158d0009a631ac', payload '{"last_seen":"2024-01-29T20:34:09+01:00","linkquality":65}' debug 2024-01-29 20:34:10: Received Zigbee message from '0x00158d0009a631ac', type 'commandColorLoopSet', cluster 'lightingColorCtrl', data '{"action":0,"direction":0,"starthue":0,"time":0,"updateflags":15}' from endpoint 1 with groupID 2 debug 2024-01-29 20:34:10: No converter available for '50067' with cluster 'lightingColorCtrl' and type 'commandColorLoopSet' and data '{"action":0,"direction":0,"starthue":0,"time":0,"updateflags":15}' info 2024-01-29 20:34:10: MQTT publish: topic 'zigbee2mqtt/0x00158d0009a631ac', payload '{"last_seen":"2024-01-29T20:34:10+01:00","linkquality":61}' debug 2024-01-29 20:34:10: Received Zigbee message from '0x00158d0009a631ac', type 'commandEnhancedMoveToHueAndSaturation', cluster 'lightingColorCtrl', data '{"enhancehue":15467,"saturation":254,"transtime":1}' from endpoint 1 with groupID 2 debug 2024-01-29 20:34:10: No converter available for '50067' with cluster 'lightingColorCtrl' and type 'commandEnhancedMoveToHueAndSaturation' and data '{"enhancehue":15467,"saturation":254,"transtime":1}' info 2024-01-29 20:34:10: MQTT publish: topic 'zigbee2mqtt/0x00158d0009a631ac', payload '{"last_seen":"2024-01-29T20:34:10+01:00","linkquality":65}' debug 2024-01-29 20:34:11: Received Zigbee message from '0x00158d0009a631ac', type 'commandMove', cluster 'genLevelCtrl', data '{"movemode":1,"rate":100}' from endpoint 1 with groupID 2 debug 2024-01-29 20:34:11: No converter available for '50067' with cluster 'genLevelCtrl' and type 'commandMove' and data '{"movemode":1,"rate":100}' info 2024-01-29 20:34:11: MQTT publish: topic 'zigbee2mqtt/0x00158d0009a631ac', payload '{"last_seen":"2024-01-29T20:34:11+01:00","linkquality":65}' debug 2024-01-29 20:34:11: Received Zigbee message from '0x00158d0009a631ac', type 'commandStop', cluster 'genLevelCtrl', data '{}' from endpoint 1 with groupID 2 debug 2024-01-29 20:34:11: No converter available for '50067' with cluster 'genLevelCtrl' and type 'commandStop' and data '{}' info 2024-01-29 20:34:11: MQTT publish: topic 'zigbee2mqtt/0x00158d0009a631ac', payload '{"last_seen":"2024-01-29T20:34:11+01:00","linkquality":61}' debug 2024-01-29 20:34:11: Received Zigbee message from '0x00158d0009a631ac', type 'commandMove', cluster 'genLevelCtrl', data '{"movemode":1,"rate":100}' from endpoint 1 with groupID 2 debug 2024-01-29 20:34:11: No converter available for '50067' with cluster 'genLevelCtrl' and type 'commandMove' and data '{"movemode":1,"rate":100}' info 2024-01-29 20:34:11: MQTT publish: topic 'zigbee2mqtt/0x00158d0009a631ac', payload '{"last_seen":"2024-01-29T20:34:11+01:00","linkquality":61}' debug 2024-01-29 20:34:11: Received Zigbee message from '0x00158d0009a631ac', type 'commandStop', cluster 'genLevelCtrl', data '{}' from endpoint 1 with groupID 2 debug 2024-01-29 20:34:11: No converter available for '50067' with cluster 'genLevelCtrl' and type 'commandStop' and data '{}' info 2024-01-29 20:34:11: MQTT publish: topic 'zigbee2mqtt/0x00158d0009a631ac', payload '{"last_seen":"2024-01-29T20:34:11+01:00","linkquality":61}' debug 2024-01-29 20:34:11: Received Zigbee message from '0x00158d0009a631ac', type 'commandMove', cluster 'genLevelCtrl', data '{"movemode":1,"rate":100}' from endpoint 1 with groupID 2 debug 2024-01-29 20:34:11: No converter available for '50067' with cluster 'genLevelCtrl' and type 'commandMove' and data '{"movemode":1,"rate":100}' info 2024-01-29 20:34:11: MQTT publish: topic 'zigbee2mqtt/0x00158d0009a631ac', payload '{"last_seen":"2024-01-29T20:34:11+01:00","linkquality":58}' debug 2024-01-29 20:34:11: Received Zigbee message from '0x00158d0009a631ac', type 'commandStop', cluster 'genLevelCtrl', data '{}' from endpoint 1 with groupID 2 debug 2024-01-29 20:34:11: No converter available for '50067' with cluster 'genLevelCtrl' and type 'commandStop' and data '{}' info 2024-01-29 20:34:11: MQTT publish: topic 'zigbee2mqtt/0x00158d0009a631ac', payload '{"last_seen":"2024-01-29T20:34:11+01:00","linkquality":61}' debug 2024-01-29 20:34:11: Received Zigbee message from '0x00158d0009a631ac', type 'commandMove', cluster 'genLevelCtrl', data '{"movemode":1,"rate":100}' from endpoint 1 with groupID 2 debug 2024-01-29 20:34:11: No converter available for '50067' with cluster 'genLevelCtrl' and type 'commandMove' and data '{"movemode":1,"rate":100}' info 2024-01-29 20:34:11: MQTT publish: topic 'zigbee2mqtt/0x00158d0009a631ac', payload '{"last_seen":"2024-01-29T20:34:11+01:00","linkquality":65}' debug 2024-01-29 20:34:11: Received Zigbee message from '0x00158d0009a631ac', type 'commandStop', cluster 'genLevelCtrl', data '{}' from endpoint 1 with groupID 2 debug 2024-01-29 20:34:11: No converter available for '50067' with cluster 'genLevelCtrl' and type 'commandStop' and data '{}' info 2024-01-29 20:34:11: MQTT publish: topic 'zigbee2mqtt/0x00158d0009a631ac', payload '{"last_seen":"2024-01-29T20:34:11+01:00","linkquality":61}' debug 2024-01-29 20:34:11: Received Zigbee message from '0x00158d0009a631ac', type 'commandMove', cluster 'genLevelCtrl', data '{"movemode":1,"rate":100}' from endpoint 1 with groupID 2 debug 2024-01-29 20:34:11: No converter available for '50067' with cluster 'genLevelCtrl' and type 'commandMove' and data '{"movemode":1,"rate":100}' info 2024-01-29 20:34:11: MQTT publish: topic 'zigbee2mqtt/0x00158d0009a631ac', payload '{"last_seen":"2024-01-29T20:34:11+01:00","linkquality":61}' debug 2024-01-29 20:34:11: Received Zigbee message from '0x00158d0009a631ac', type 'commandStop', cluster 'genLevelCtrl', data '{}' from endpoint 1 with groupID 2 debug 2024-01-29 20:34:11: No converter available for '50067' with cluster 'genLevelCtrl' and type 'commandStop' and data '{}' info 2024-01-29 20:34:11: MQTT publish: topic 'zigbee2mqtt/0x00158d0009a631ac', payload '{"last_seen":"2024-01-29T20:34:11+01:00","linkquality":58}' debug 2024-01-29 20:34:12: Received Zigbee message from '0x00158d0009a631ac', type 'commandMove', cluster 'genLevelCtrl', data '{"movemode":1,"rate":100}' from endpoint 1 with groupID 2 debug 2024-01-29 20:34:12: No converter available for '50067' with cluster 'genLevelCtrl' and type 'commandMove' and data '{"movemode":1,"rate":100}' info 2024-01-29 20:34:12: MQTT publish: topic 'zigbee2mqtt/0x00158d0009a631ac', payload '{"last_seen":"2024-01-29T20:34:12+01:00","linkquality":61}' debug 2024-01-29 20:34:12: Received Zigbee message from '0x00158d0009a631ac', type 'commandStop', cluster 'genLevelCtrl', data '{}' from endpoint 1 with groupID 2 debug 2024-01-29 20:34:12: No converter available for '50067' with cluster 'genLevelCtrl' and type 'commandStop' and data '{}' info 2024-01-29 20:34:12: MQTT publish: topic 'zigbee2mqtt/0x00158d0009a631ac', payload '{"last_seen":"2024-01-29T20:34:12+01:00","linkquality":58}' debug 2024-01-29 20:34:12: Received Zigbee message from '0x00158d0009a631ac', type 'commandMove', cluster 'genLevelCtrl', data '{"movemode":1,"rate":100}' from endpoint 1 with groupID 2 debug 2024-01-29 20:34:12: No converter available for '50067' with cluster 'genLevelCtrl' and type 'commandMove' and data '{"movemode":1,"rate":100}' info 2024-01-29 20:34:12: MQTT publish: topic 'zigbee2mqtt/0x00158d0009a631ac', payload '{"last_seen":"2024-01-29T20:34:12+01:00","linkquality":61}' debug 2024-01-29 20:34:12: Received Zigbee message from '0x00158d0009a631ac', type 'commandStop', cluster 'genLevelCtrl', data '{}' from endpoint 1 with groupID 2 debug 2024-01-29 20:34:12: No converter available for '50067' with cluster 'genLevelCtrl' and type 'commandStop' and data '{}' info 2024-01-29 20:34:12: MQTT publish: topic 'zigbee2mqtt/0x00158d0009a631ac', payload '{"last_seen":"2024-01-29T20:34:12+01:00","linkquality":61}' debug 2024-01-29 20:34:12: Received Zigbee message from '0x00158d0009a631ac', type 'commandMove', cluster 'genLevelCtrl', data '{"movemode":0,"rate":100}' from endpoint 1 with groupID 2 debug 2024-01-29 20:34:12: No converter available for '50067' with cluster 'genLevelCtrl' and type 'commandMove' and data '{"movemode":0,"rate":100}' info 2024-01-29 20:34:12: MQTT publish: topic 'zigbee2mqtt/0x00158d0009a631ac', payload '{"last_seen":"2024-01-29T20:34:12+01:00","linkquality":61}' debug 2024-01-29 20:34:13: Received Zigbee message from '0x00158d0009a631ac', type 'commandStop', cluster 'genLevelCtrl', data '{}' from endpoint 1 with groupID 2 debug 2024-01-29 20:34:13: No converter available for '50067' with cluster 'genLevelCtrl' and type 'commandStop' and data '{}' info 2024-01-29 20:34:13: MQTT publish: topic 'zigbee2mqtt/0x00158d0009a631ac', payload '{"last_seen":"2024-01-29T20:34:13+01:00","linkquality":65}' debug 2024-01-29 20:34:13: Received Zigbee message from '0x00158d0009a631ac', type 'commandMove', cluster 'genLevelCtrl', data '{"movemode":0,"rate":100}' from endpoint 1 with groupID 2 debug 2024-01-29 20:34:13: No converter available for '50067' with cluster 'genLevelCtrl' and type 'commandMove' and data '{"movemode":0,"rate":100}' info 2024-01-29 20:34:13: MQTT publish: topic 'zigbee2mqtt/0x00158d0009a631ac', payload '{"last_seen":"2024-01-29T20:34:13+01:00","linkquality":61}' debug 2024-01-29 20:34:13: Received Zigbee message from '0x00158d0009a631ac', type 'commandStop', cluster 'genLevelCtrl', data '{}' from endpoint 1 with groupID 2 debug 2024-01-29 20:34:13: No converter available for '50067' with cluster 'genLevelCtrl' and type 'commandStop' and data '{}' info 2024-01-29 20:34:13: MQTT publish: topic 'zigbee2mqtt/0x00158d0009a631ac', payload '{"last_seen":"2024-01-29T20:34:13+01:00","linkquality":58}' debug 2024-01-29 20:34:13: Received Zigbee message from '0x00158d0009a631ac', type 'commandMove', cluster 'genLevelCtrl', data '{"movemode":0,"rate":100}' from endpoint 1 with groupID 2 debug 2024-01-29 20:34:13: No converter available for '50067' with cluster 'genLevelCtrl' and type 'commandMove' and data '{"movemode":0,"rate":100}' info 2024-01-29 20:34:13: MQTT publish: topic 'zigbee2mqtt/0x00158d0009a631ac', payload '{"last_seen":"2024-01-29T20:34:13+01:00","linkquality":65}' debug 2024-01-29 20:34:13: Received Zigbee message from '0x00158d0009a631ac', type 'commandStop', cluster 'genLevelCtrl', data '{}' from endpoint 1 with groupID 2 debug 2024-01-29 20:34:13: No converter available for '50067' with cluster 'genLevelCtrl' and type 'commandStop' and data '{}' info 2024-01-29 20:34:13: MQTT publish: topic 'zigbee2mqtt/0x00158d0009a631ac', payload '{"last_seen":"2024-01-29T20:34:13+01:00","linkquality":58}' debug 2024-01-29 20:34:13: Received Zigbee message from '0x00158d0009a631ac', type 'commandMove', cluster 'genLevelCtrl', data '{"movemode":0,"rate":100}' from endpoint 1 with groupID 2 debug 2024-01-29 20:34:13: No converter available for '50067' with cluster 'genLevelCtrl' and type 'commandMove' and data '{"movemode":0,"rate":100}' info 2024-01-29 20:34:13: MQTT publish: topic 'zigbee2mqtt/0x00158d0009a631ac', payload '{"last_seen":"2024-01-29T20:34:13+01:00","linkquality":61}' debug 2024-01-29 20:34:13: Received Zigbee message from '0x00158d0009a631ac', type 'commandStop', cluster 'genLevelCtrl', data '{}' from endpoint 1 with groupID 2 debug 2024-01-29 20:34:13: No converter available for '50067' with cluster 'genLevelCtrl' and type 'commandStop' and data '{}' info 2024-01-29 20:34:13: MQTT publish: topic 'zigbee2mqtt/0x00158d0009a631ac', payload '{"last_seen":"2024-01-29T20:34:13+01:00","linkquality":61}' debug 2024-01-29 20:34:14: Received Zigbee message from '0x00158d0009a631ac', type 'commandMove', cluster 'genLevelCtrl', data '{"movemode":0,"rate":100}' from endpoint 1 with groupID 2 debug 2024-01-29 20:34:14: No converter available for '50067' with cluster 'genLevelCtrl' and type 'commandMove' and data '{"movemode":0,"rate":100}' info 2024-01-29 20:34:14: MQTT publish: topic 'zigbee2mqtt/0x00158d0009a631ac', payload '{"last_seen":"2024-01-29T20:34:14+01:00","linkquality":58}' debug 2024-01-29 20:34:14: Received Zigbee message from '0x00158d0009a631ac', type 'commandStop', cluster 'genLevelCtrl', data '{}' from endpoint 1 with groupID 2 debug 2024-01-29 20:34:14: No converter available for '50067' with cluster 'genLevelCtrl' and type 'commandStop' and data '{}' info 2024-01-29 20:34:14: MQTT publish: topic 'zigbee2mqtt/0x00158d0009a631ac', payload '{"last_seen":"2024-01-29T20:34:14+01:00","linkquality":61}' debug 2024-01-29 20:34:14: Received Zigbee message from '0x00158d0009a631ac', type 'commandMove', cluster 'genLevelCtrl', data '{"movemode":0,"rate":100}' from endpoint 1 with groupID 2 debug 2024-01-29 20:34:14: No converter available for '50067' with cluster 'genLevelCtrl' and type 'commandMove' and data '{"movemode":0,"rate":100}' info 2024-01-29 20:34:14: MQTT publish: topic 'zigbee2mqtt/0x00158d0009a631ac', payload '{"last_seen":"2024-01-29T20:34:14+01:00","linkquality":61}' debug 2024-01-29 20:34:14: Received Zigbee message from '0x00158d0009a631ac', type 'commandStop', cluster 'genLevelCtrl', data '{}' from endpoint 1 with groupID 2 debug 2024-01-29 20:34:14: No converter available for '50067' with cluster 'genLevelCtrl' and type 'commandStop' and data '{}' info 2024-01-29 20:34:14: MQTT publish: topic 'zigbee2mqtt/0x00158d0009a631ac', payload '{"last_seen":"2024-01-29T20:34:14+01:00","linkquality":58}' debug 2024-01-29 20:34:14: Received Zigbee message from '0x00158d0009a631ac', type 'commandMove', cluster 'genLevelCtrl', data '{"movemode":0,"rate":100}' from endpoint 1 with groupID 2 debug 2024-01-29 20:34:14: No converter available for '50067' with cluster 'genLevelCtrl' and type 'commandMove' and data '{"movemode":0,"rate":100}' info 2024-01-29 20:34:14: MQTT publish: topic 'zigbee2mqtt/0x00158d0009a631ac', payload '{"last_seen":"2024-01-29T20:34:14+01:00","linkquality":51}' debug 2024-01-29 20:34:14: Received Zigbee message from '0x00158d0009a631ac', type 'commandStop', cluster 'genLevelCtrl', data '{}' from endpoint 1 with groupID 2 debug 2024-01-29 20:34:14: No converter available for '50067' with cluster 'genLevelCtrl' and type 'commandStop' and data '{}' info 2024-01-29 20:34:14: MQTT publish: topic 'zigbee2mqtt/0x00158d0009a631ac', payload '{"last_seen":"2024-01-29T20:34:14+01:00","linkquality":51}' debug 2024-01-29 20:34:14: Received Zigbee message from '0x00158d0009a631ac', type 'commandMove', cluster 'genLevelCtrl', data '{"movemode":0,"rate":100}' from endpoint 1 with groupID 2 debug 2024-01-29 20:34:14: No converter available for '50067' with cluster 'genLevelCtrl' and type 'commandMove' and data '{"movemode":0,"rate":100}' info 2024-01-29 20:34:14: MQTT publish: topic 'zigbee2mqtt/0x00158d0009a631ac', payload '{"last_seen":"2024-01-29T20:34:14+01:00","linkquality":58}' debug 2024-01-29 20:34:14: Received Zigbee message from '0x00158d0009a631ac', type 'commandStop', cluster 'genLevelCtrl', data '{}' from endpoint 1 with groupID 2 debug 2024-01-29 20:34:14: No converter available for '50067' with cluster 'genLevelCtrl' and type 'commandStop' and data '{}' info 2024-01-29 20:34:14: MQTT publish: topic 'zigbee2mqtt/0x00158d0009a631ac', payload '{"last_seen":"2024-01-29T20:34:14+01:00","linkquality":61}' debug 2024-01-29 20:34:14: Received Zigbee message from '0x00158d0009a631ac', type 'commandMove', cluster 'genLevelCtrl', data '{"movemode":0,"rate":100}' from endpoint 1 with groupID 2 debug 2024-01-29 20:34:14: No converter available for '50067' with cluster 'genLevelCtrl' and type 'commandMove' and data '{"movemode":0,"rate":100}' info 2024-01-29 20:34:14: MQTT publish: topic 'zigbee2mqtt/0x00158d0009a631ac', payload '{"last_seen":"2024-01-29T20:34:14+01:00","linkquality":58}' debug 2024-01-29 20:34:15: Received Zigbee message from '0x00158d0009a631ac', type 'commandStop', cluster 'genLevelCtrl', data '{}' from endpoint 1 with groupID 2 debug 2024-01-29 20:34:15: No converter available for '50067' with cluster 'genLevelCtrl' and type 'commandStop' and data '{}' info 2024-01-29 20:34:15: MQTT publish: topic 'zigbee2mqtt/0x00158d0009a631ac', payload '{"last_seen":"2024-01-29T20:34:15+01:00","linkquality":58}' debug 2024-01-29 20:34:15: Received Zigbee message from '0x00158d0009a631ac', type 'commandMove', cluster 'genLevelCtrl', data '{"movemode":0,"rate":100}' from endpoint 1 with groupID 2 debug 2024-01-29 20:34:15: No converter available for '50067' with cluster 'genLevelCtrl' and type 'commandMove' and data '{"movemode":0,"rate":100}' info 2024-01-29 20:34:15: MQTT publish: topic 'zigbee2mqtt/0x00158d0009a631ac', payload '{"last_seen":"2024-01-29T20:34:15+01:00","linkquality":54}' debug 2024-01-29 20:34:15: Received Zigbee message from '0x00158d0009a631ac', type 'commandStop', cluster 'genLevelCtrl', data '{}' from endpoint 1 with groupID 2 debug 2024-01-29 20:34:15: No converter available for '50067' with cluster 'genLevelCtrl' and type 'commandStop' and data '{}' info 2024-01-29 20:34:15: MQTT publish: topic 'zigbee2mqtt/0x00158d0009a631ac', payload '{"last_seen":"2024-01-29T20:34:15+01:00","linkquality":61}' debug 2024-01-29 20:34:15: Received MQTT message on 'zigbee2mqtt/bridge/request/options' with data '{"options":{"advanced":{"log_level":"info"}},"transaction":"6za80-5"}' info 2024-01-29 20:34:15: Successfully changed options info 2024-01-29 20:34:15: MQTT publish: topic 'zigbee2mqtt/bridge/response/options', payload '{"data":{"restart_required":false},"status":"ok","transaction":"6za80-5"}' info 2024-01-29 20:34:28: MQTT publish: topic 'zigbee2mqtt/KU_Light_Middle', payload '{"brightness":102,"color_mode":"color_temp","color_temp":245,"color_temp_startup":370,"last_seen":"2024-01-29T20:34:28+01:00","linkquality":83,"power_on_behavior":"off","state":"OFF"}' info 2024-01-29 20:34:40: MQTT publish: topic 'zigbee2mqtt/GT_Light_Terrasse', payload '{"brightness":51,"last_seen":"2024-01-29T20:34:40+01:00","linkquality":80,"power_on_behavior":"off","state":"ON"}' info 2024-01-29 20:34:40: MQTT publish: topic 'zigbee2mqtt/KU_Light_Left', payload '{"brightness":51,"color_mode":"color_temp","color_temp":153,"color_temp_startup":153,"last_seen":"2024-01-29T20:34:40+01:00","linkquality":80,"power_on_behavior":"off","state":"OFF"}'

derMicro commented 7 months ago

I have found the error, the device is listed in paulmann.ts, but it has a different "zigbeeModel" there

paulmann.ts: { zigbeeModel: ['RemoteControl'], model: '500.67', vendor: 'Paulmann', description: 'RGB remote control', fromZigbee: [fz.command_on, fz.command_off, fz.command_toggle, fz.command_step, fz.command_move_to_color_temp, fz.command_move_to_color, fz.command_stop, fz.command_move, fz.command_color_loop_set, fz.command_ehanced_move_to_hue_and_saturation, fz.tint_scene], toZigbee: [], exposes: [e.action([ 'on', 'off', 'toggle', 'brightness_step_up', 'brightness_step_down', 'color_temperature_move', 'color_move', 'brightness_stop', 'brightness_move_down', 'brightness_move_up', 'color_loop_set', 'enhanced_move_to_hue_and_saturation', 'scene_*'])], },

Fix for my device: const definition = { zigbeeModel: ['50067'], model: '50067', vendor: 'Paulmann Licht GmbH', description: 'RGB remote control', extend: [], fromZigbee: [fz.command_on, fz.command_off, fz.command_toggle, fz.command_step, fz.command_move_to_color_temp, fz.command_move_to_color, fz.command_stop, fz.command_move, fz.command_color_loop_set, fz.command_ehanced_move_to_hue_and_saturation, fz.tint_scene], toZigbee: [], exposes: [e.action(['on', 'off', 'toggle', 'brightness_step_up', 'brightness_step_down', 'color_temperature_move', 'color_move', 'brightness_stop', 'brightness_move_down', 'brightness_move_up', 'color_loop_set', 'enhanced_move_to_hue_and_saturation', 'scene_*'])], };

github-actions[bot] commented 1 month ago

This issue is stale because it has been open 180 days with no activity. Remove stale label or comment or this will be closed in 30 days

cadimmek commented 4 weeks ago

I had the same problem. Using the provided solution from @derMicro solved it for me