Smart Sprinkler Timer water metering #22813

Open derekangl opened 5 months ago

derekangl commented 5 months ago

Link

https://www.ebay.co.uk/itm/355700417511

Database entry

{"id":21,"type":"EndDevice","ieeeAddr":"0xa4c13869455a3642","nwkAddr":26812,"manufId":4417,"manufName":"_TZE204_uab532m0","powerSource":"Battery","modelId":"TS0601","epList":[1],"endpoints":{"1":{"profId":260,"epId":1,"devId":81,"inClusterList":[0,4,5,61184],"outClusterList":[25,10],"clusters":{"genBasic":{"attributes":{"65487":14400,"65503":"b��-fc��-\u0012","65506":56,"65508":0,"stackVersion":0,"dateCode":"","appVersion":74}}},"binds":[],"configuredReportings":[],"meta":{}}},"appVersion":74,"stackVersion":0,"hwVersion":1,"dateCode":"","zclVersion":3,"interviewCompleted":true,"meta":{},"lastSeen":1716919405582}

Comments

hi, can you hellp me sport new device.Please. 20240528_182911 20240528_182853 (1)

const definition = { zigbeeModel: ['TS0601'], model: 'TS0601', vendor: '_TZE204_uab532m0', description: 'Automatically generated definition', extend: [], meta: {},

External definition

q
derekangl commented 5 months ago

logs Info 2024-05-31 20:31:21Succesfully interviewed '0xa4c13869455a3642' Info 2024-05-31 20:31:21Successfully interviewed '0xa4c13869455a3642', device has successfully been paired Info 2024-05-31 20:31:21Device '0xa4c13869455a3642' is supported, identified as: tuya water_valve here (TS0601_new) Info 2024-05-31 20:31:22MQTT publish: topic 'z2mR22/bridge/event', payload '{"data":{"definition":{"description":"water_valve here","exposes":[{"access":1,"category":"diagnostic","description":"Link quality (signal strength)","label":"Linkquality","name":"linkquality","property":"linkquality","type":"numeric","unit":"lqi","value_max":255,"value_min":0}],"model":"TS0601_new","options":[],"supports_ota":false,"vendor":"tuya"},"friendly_name":"0xa4c13869455a3642","ieee_address":"0xa4c13869455a3642","status":"successful","supported":true},"type":"device_interview"}' Info 2024-05-31 20:31:22Configuring '0xa4c13869455a3642' Info 2024-05-31 20:31:22MQTT publish: topic 'homeassistant/sensor/0xa4c13869455a3642/linkquality/config', payload '{"availability":[{"topic":"z2mR22/bridge/state","value_template":"{{ value_json.state }}"},{"topic":"z2mR22/0xa4c13869455a3642/availability","value_template":"{{ value_json.state }}"}],"availability_mode":"all","device":{"identifiers":["zigbee2mqtt_0xa4c13869455a3642"],"manufacturer":"tuya","model":"water_valve here (TS0601_new)","name":"0xa4c13869455a3642","via_device":"zigbee2mqtt_bridge_0x04cd15fffee45691"},"enabled_by_default":false,"entity_category":"diagnostic","icon":"mdi:signal","json_attributes_topic":"z2mR22/0xa4c13869455a3642","name":"Linkquality","object_id":"0xa4c13869455a3642_linkquality","origin":{"name":"Zigbee2MQTT","sw":"1.37.1-dev","url":"https://www.zigbee2mqtt.io"},"state_class":"measurement","state_topic":"z2mR22/0xa4c13869455a3642","unique_id":"0xa4c13869455a3642_linkquality_z2mR22","unit_of_measurement":"lqi","value_template":"{{ value_json.linkquality }}"}' Info 2024-05-31 20:31:22Successfully configured '0xa4c13869455a3642'

and

const fz = require('zigbee-herdsman-converters/converters/fromZigbee'); const tz = require('zigbee-herdsman-converters/converters/toZigbee'); const exposes = require('zigbee-herdsman-converters/lib/exposes'); const reporting = require('zigbee-herdsman-converters/lib/reporting'); const modernExtend = require('zigbee-herdsman-converters/lib/modernExtend'); const e = exposes.presets; const ea = exposes.access; const tuya = require('zigbee-herdsman-converters/lib/tuya');

const definition = { // Since a lot of TuYa devices use the same modelID, but use different datapoints // it's necessary to provide a fingerprint instead of a zigbeeModel fingerprint: [ { // The model ID from: Device with modelID 'TS0601' is not supported // You may need to add \u0000 at the end of the name in some cases modelID: 'TS0601', // The manufacturer name from: Device with modelID 'TS0601' is not supported. manufacturerName: '_TZE204_uab532m0', }, ], model: 'TS0601_new', vendor: 'tuya', description: 'water_valve here', fromZigbee: [tuya.fz.datapoints], toZigbee: [tuya.tz.datapoints], onEvent: tuya.onEventSetTime, // Add this if you are getting no converter for 'commandMcuSyncTime' configure: tuya.configureMagicPacket, exposes: [ // Here you should put all functionality that your device exposes ], meta: { // All datapoints go in here tuyaDatapoints: [ ], }, extend: [

    // A preferred new way of extending functionality.
],

};

module.exports = definition;

dominique6017 commented 5 months ago

I have the same valve and have found the tuya end point : {"1":"Switch", boolean "3":"Status", "type": "Enum", "values": "{\"range\":[\"off\",\"auto\",\"disabled\"]}" "5":"Countdown", "type": "Integer", "values": "{\"unit\":\"min\",\"min\":1,\"max\":240,\"scale\":0,\"step\":1}" "6":"Countdown Left", "type": "Integer", "values": "{\"unit\":\"min\",\"min\":1,\"max\":240,\"scale\":0,\"step\":1}" "9":"Water Current" "type": "Integer", "values": "{\"unit\":\"gal/min\",\"min\":0,\"max\":1000000000,\"scale\":3,\"step\":1}" "11":"Battery Percentage" "type": "Integer", "values": "{\"unit\":\"%\",\"min\":0,\"max\":100,\"scale\":0,\"step\":1}" "15":"Water Total" "type": "Integer", "values": "{\"unit\":\"gal\",\"min\":0,\"max\":999999999,\"scale\":3,\"step\":1}" "19":"Fault" "37":"Weather Delay", type enum {\"range\":[\"24h\",\"48h\",\"72h\",\"cancel\"]}" "38":"Normal Timer", "type": "String", "values": "{\"maxlen\":255}" "42":"Switch", boolean "47":"Smart Irrigation" "101":"Total flow reset switch", "102":"Quantitative watering", "103":"Flow switch"} "104":"Child lock" "105":"Surplus flow" "106":"Single watering time" "107":"Interface refresh", "108":"Amount of watering per time"}

I don't know to write the converter and need help

xpavli44 commented 5 months ago

@dominique6017 are you familiar with https://www.zigbee2mqtt.io/advanced/support-new-devices/01_support_new_devices.html#_2-2-adding-converter-s-for-your-device ?

xpavli44 commented 5 months ago

ohhh .... it seems it may already exist? https://github.com/Koenkk/zigbee-herdsman-converters/blob/da65b1aeffd96527df02725b49de61e453fee059/src/devices/neo.ts#L130 just needs some tweaking?

xpavli44 commented 5 months ago

@dominique6017 and/or @derekangl could you test if https://github.com/Koenkk/zigbee-herdsman-converters/pull/7670 helps with the issue? I will be able to do it in at least a week, I cannot get to my sensor earlier :(

mrespin commented 5 months ago

Hiya,

I have this valve from derekangl and came up with this converter, based on the Koenkk/zigbee-herdsman-converters#7670 NB zigbee-herdsman-converters update has not yet been merged. (latest v19.58.0). When playing with On / Off (working with 3 seconds delay), I see errors: Error 2024-06-22 02:52:20z2m: Exception while calling fromZigbee converter: Value '4' is not allowed, expected one of true,false} Error 2024-06-22 02:52:26z2m: Exception while calling fromZigbee converter: Value '0' is not allowed, expected one of true,false} Error 2024-06-22 02:52:27z2m: No converter available for 'get' 'state' () Error 2024-06-22 02:52:32z2m: Exception while calling fromZigbee converter: Value '3' is not allowed, expected one of true,false} Error 2024-06-22 02:53:02z2m: Exception while calling fromZigbee converter: Value '0' is not allowed, expected one of true,false} Error 2024-06-22 02:56:54z2m: No converter available for 'switch_enabled' ("ON") Error 2024-06-22 02:56:55z2m: No converter available for 'switch_enabled' ("OFF") Error 2024-06-22 02:57:00z2m: No converter available for 'total_flow_reset_switch' ("OFF") Error 2024-06-22 02:57:01z2m: No converter available for 'total_flow_reset_switch' ("ON") Error 2024-06-22 02:57:02z2m: No converter available for 'flow_switch' ("OFF") Error 2024-06-22 02:57:04z2m: No converter available for 'flow_switch' ("ON") Error 2024-06-22 02:56:45z2m: No converter available for 'get' 'state' () Error 2024-06-22 02:56:54z2m: No converter available for 'switch_enabled' ("ON") Error 2024-06-22 02:56:55z2m: No converter available for 'switch_enabled' ("OFF") Error 2024-06-22 02:57:00z2m: No converter available for 'total_flow_reset_switch' ("OFF") Error 2024-06-22 02:57:01z2m: No converter available for 'total_flow_reset_switch' ("ON") Error 2024-06-22 02:57:02z2m: No converter available for 'flow_switch' ("OFF") Error 2024-06-22 02:57:04z2m: No converter available for 'flow_switch' ("ON") Error 2024-06-22 03:32:49z2m: No converter available for 'weather_delay' ("24h")

Moreover, NULLS: Status Null Water current Current water flow (L/min) NullL/min Battery percentage Null% Water total Total water flow (L) NullL Fault Fault status Null Smart irrigation Null Surplus flow Null Single watering duration Null Single watering amount Null

External converter:

const fz = require('zigbee-herdsman-converters/converters/fromZigbee'); const tz = require('zigbee-herdsman-converters/converters/toZigbee'); const exposes = require('zigbee-herdsman-converters/lib/exposes'); const reporting = require('zigbee-herdsman-converters/lib/reporting'); const {} = require('zigbee-herdsman-converters/lib/modernExtend'); const e = exposes.presets; const ea = exposes.access; const tuya = require('zigbee-herdsman-converters/lib/tuya'); const legacy = require('zigbee-herdsman-converters/lib/legacy')

const definition = { fingerprint: tuya.fingerprint('TS0601', ['_TZE204_uab532m0']), zigbeeModel: ['NAS-WV03B'], model: 'NAS-WV03B_Jac', vendor: 'Neo', fromZigbee: [tuya.fz.datapoints], toZigbee: [tuya.tz.datapoints], description: 'Smart sprinkler timer', onEvent: tuya.onEventSetTime, configure: tuya.configureMagicPacket, exposes: [ e.switch(), e.enum('status', ea.STATE, ['off', 'auto', 'disabled']).withDescription('Status'), e.numeric('countdown', ea.STATE_SET).withUnit('min').withValueMin(1).withValueMax(240).withDescription('Countdown'), e.numeric('countdown_left', ea.STATE).withUnit('min').withValueMin(1).withValueMax(240).withDescription('Countdown left'), e.numeric('water_current', ea.STATE).withUnit('L/min').withValueMin(0).withValueMax(3785.41).withValueStep(0.001) .withDescription('Current water flow (L/min)'), e.numeric('battery_percentage', ea.STATE).withUnit('%').withValueMin(0).withValueMax(100).withDescription('Battery percentage'), e.numeric('water_total', ea.STATE).withUnit('L').withValueMin(0).withValueMax(378541.0).withValueStep(0.001) .withDescription('Total water flow (L)'), e.binary('fault', ea.STATE, 'DETECTED', 'NOT_DETECTED').withDescription('Fault status'), e.enum('weather_delay', ea.STATE_SET, ['24h', '48h', '72h', 'cancel']).withDescription('Weather delay'), e.text('normal_timer', ea.STATE_SET).withDescription('Normal timer'), e.binary('switch_enabled', ea.STATE_SET, 'ON', 'OFF').withDescription('Switch enabled'), e.numeric('smart_irrigation', ea.STATE).withDescription('Smart irrigation'), e.binary('total_flow_reset_switch', ea.STATE_SET, 'ON', 'OFF').withDescription('Total flow reset switch'), e.numeric('quantitative_watering', ea.STATE_SET).withUnit('L').withValueMin(0).withValueMax(10000) .withDescription('Quantitative watering'), e.binary('flow_switch', ea.STATE_SET, 'ON', 'OFF').withDescription('Flow switch'), e.binary('child_lock', ea.STATE_SET, 'ON', 'OFF').withDescription('Child lock'), e.numeric('surplus_flow', ea.STATE).withDescription('Surplus flow'), e.numeric('single_watering_duration', ea.STATE).withDescription('Single watering duration'), e.numeric('single_watering_amount', ea.STATE).withDescription('Single watering amount'), ], meta: { tuyaDatapoints: [ [1, 'state', tuya.valueConverter.onOff], [3, 'status', tuya.valueConverter.onOff], [5, 'countdown', tuya.valueConverter.raw], [6, 'countdown_left', tuya.valueConverter.raw], [9, 'water_current', tuya.valueConverter.raw], [11, 'battery_percentage', tuya.valueConverter.batteryState], [15, 'water_total', tuya.valueConverter.raw], [19, 'fault', tuya.valueConverter.raw], [37, 'weather_delay', tuya.valueConverter.raw], [38, 'normal_timer', tuya.valueConverter.raw], [42, 'switch_enabled', tuya.valueConverter.onOff], [47, 'smart_irrigation', tuya.valueConverter.raw], [101, 'total_flow_reset_switch', tuya.valueConverter.onOff], [102, 'quantitative_watering', tuya.valueConverter.raw], [103, 'flow_switch', tuya.valueConverter.onOff], [104, 'child_lock', tuya.valueConverter.onOff], [105, 'surplus_flow', tuya.valueConverter.raw], [106, 'single_watering_duration', tuya.valueConverter.raw], [108, 'single_watering_amount', tuya.valueConverter.raw], ], }, };

module.exports = definition;

OgV1 commented 5 months ago

ohhh .... it seems it may already exist? https://github.com/Koenkk/zigbee-herdsman-converters/blob/da65b1aeffd96527df02725b49de61e453fee059/src/devices/neo.ts#L130 just needs some tweaking?

Hi Guys,

I have created that converter based on this fingerprint _TZE204_rzrrjkz2 in this pull request

And actually not sure if I did it right, because I still don't have a chance to test with my own device (Guess it because the fingerprint is now _TZE204_uab532m0 and not the same as mine _TZE204_rzrrjkz2?)

Anyone have any idea how to solve this? and why do we have different fingerprints on the same device?

edit: Somehow, mine was slightly different with no Neo logo on it, is there any chances that it not actually Neo's ? image

FYI this is the info from my vendor: he seems to be sure that this one is Neo's with model number NAS-WV03B

xpavli44 commented 5 months ago

And actually not sure if I did it right, because I still don't have a chance to test with my own device (Guess it because the fingerprint is now _TZE204_uab532m0 and not the same as mine _TZE204_rzrrjkz2?)

you should be able to add your fingerprint as well just change this line to something like

fingerprint: tuya.fingerprint('TS0601', ['_TZE204_uab532m0', ' _TZE204_rzrrjkz2']),

having multiple fingerprints is quite common for TuYa devices. Probably different vendors are just using whitelabled TuYa device. See example a few lines above

if your device did not get recognized in Z2M it was probably due to the lack of the fingerprint, as TuYa makes a mess in the identifications by reusing them incorrectly.

OgV1 commented 5 months ago

@xpavli44 Thanks man,

And about further investigation for these errors do you have any idea where to start?

xpavli44 commented 5 months ago

@OgV1 unfortunately no clue :(

best I can see is

Now set the Zigbee2MQTT log_level to debug and enable the external definition by adding the following to your Zigbee2MQTT configuration.yaml.

as per https://www.zigbee2mqtt.io/advanced/support-new-devices/01_support_new_devices.html#_2-creating-the-external-definition

maybe it will provide a little more insight into the errors?

oliverwoodings commented 5 months ago

I got one of these off AliExpress, currently the stuff in neo.ts isn't working particularly well, but I've got a few things working:

But nothing else is working properly. Some things I've noticed when debugging:

Screenshot 2024-06-24 at 18 08 31

Looking at the logs, there is also definitely something wrong with commandMcuSyncTime. Even with the recommended onEvent: tuya.onEventSetTime , this comes up:

[2024-06-24 17:56:35] debug:    z2m: Received Zigbee message from 'zigbee-garden-water-valve', type 'commandMcuSyncTime', cluster 'manuSpecificTuya', data '{"payloadSize":116}' from endpoint 1 with groupID 0
[2024-06-24 17:56:35] debug:    zh:controller:endpoint: ZCL command 0xa4c1386d144eb8bf/1 manuSpecificTuya.mcuSyncTime({"payloadSize":8,"payload":[102,121,165,67,102,121,179,83]}, {"timeout":10000,"disableResponse":false,"disableRecovery":false,"disableDefaultResponse":false,"direction":0,"srcEndpoint":null,"reservedBits":0,"manufacturerCode":null,"transactionSequenceNumber":null,"writeUndiv":false})
[2024-06-24 17:56:35] debug:    z2m: No converter available for 'NAS-WV03B' with cluster 'manuSpecificTuya' and type 'commandMcuSyncTime' and data '{"payloadSize":116}'

Looking at the code in github, it looks like this might silently fail? https://github.com/Koenkk/zigbee-herdsman-converters/blob/0da0cbb88593b71f94385caeed4714d3dd0d1eb2/src/lib/tuya.ts#L192-L194

Any ideas @xpavli44 ?

OgV1 commented 5 months ago

Hi @oliverwoodings

This might be a very dumb question, I can see the latest release here, but I'm not sure how I can get it to work with my device on my system? Seems like you guys can access it and test it already, I tried to research for this but cannot find anything, could you please suggest me how to get this work?

oliverwoodings commented 5 months ago

@OgV1 by default, the version of herdsman used by z2m only updates when z2m gets a new release. I believe you can switch z2m you can either switch zg2mqtt to use the 'dev' branch, which will make it keep herdsman up to date to the latest release: https://www.zigbee2mqtt.io/advanced/more/switch-to-dev-branch.html

Personally, I've been testing using a custom external definition (using these instructions, using an adapted version of the code from neo.ts in herdsman.

OgV1 commented 5 months ago

Thanks @oliverwoodings, here's what I found according to your provided information,

  • The water flow is definitely not litres per minute - it's currently saying mine is pumping out 1483 l/min, someone call the firebrigade 😆 Perhaps it's litres per hour, but that still seems high...
  • The 'total water flow' (data point 15) is mad - at one point it was reporting massive negative numbers, and is now sitting at 15055228

The water flow unit is normally Gallon, the unit conversion to liters might be messed up.

The current exposes and DP is below

        exposes: [
            e.numeric('water_current', ea.STATE).withUnit('L/min').withValueMin(0).withValueMax(3785.41).withValueStep(0.001)
                .withDescription('Current water flow (L/min)'),

        ],

        meta: {
            tuyaDatapoints: [
                [9, 'water_current', tuya.valueConverter.raw],
            ],
        },
  • The 'status' (data point 3) is definitely not just a simple onOff - so far I've observed 4 different values. For now I have this: [3, 'status', tuya.valueConverterBasic.lookup({'off': 0, 'one': 1, 'two': 2, 'three': 3, 'four': 4})]. I've noticed that when it's off, the value is 0, when you turn it on remotely, the value is 3, and when you turn it on using the device on the button, the value is 4.

The sate should be these: 0 = Off 1 = Currently unknown 2 = Child lock activated 3 = Remotely On 4 = Physical button On

And yes the Child lock button is working

  • The battery status never reports - it's always null I tried to change the battery data point to something else, like

The current exposes and DP is below

        exposes: [
            e.battery(),
        ],

        meta: {
            tuyaDatapoints: [
                [11, 'battery', tuya.valueConverter.raw],
            ],
        },

And I found another weird behavior. Looks like after we press the button, (doesn't matter remotely or physical) the device will switch off by itself after around 30 seconds, the reason is might because that there is no water through the valve, I have to test. Edit: Alright, I have tested, doesn't stop by itself, there is nothing to worry about this.

OgV1 commented 5 months ago

Okay, looks like I can get the Battery, Status and Current water flow (L/min) to work

but somehow these ones keep showing 0 image

I can see from your image above that you somehow can make the "single_watering_amout" and "total water flow" to show the value, would you mind sharing how? @oliverwoodings image

did I missed some DPs?

oliverwoodings commented 5 months ago

Could you share your latest code? Really intrigued how you got the battery % to work, and what you did for converting to L/min.

The single watering amount and water total just randomly started working after a while, after I put a load of water through the device across a few occasions. Here's my dp's/exposes for those:

        e.numeric('water_total', ea.STATE).withUnit('L').withValueMin(0).withValueMax(378541.0).withValueStep(0.001)
            .withDescription('Total water flow (L)'),
        e.numeric('single_watering_amount', ea.STATE).withDescription('Single watering amount')
...
            [15, 'water_total', tuya.valueConverter.raw],
            [108, 'single_watering_amount', tuya.valueConverter.raw]
...

By no means complete of course.

OgV1 commented 4 months ago

Hi @oliverwoodings, sorry for late reply,

Sure, here's the battery and Current water flow L/min.

const GALLON_TO_LITER = 3.78541;

const definition = {
...
        exposes: [
...
            e.numeric('water_current', ea.STATE).withUnit('L/min').withValueMin(0).withValueMax(3785.41).withValueStep(0.1)
                .withDescription('Current water flow (L/min)'), 
            e.battery(),
...
        ],
        meta: {
            tuyaDatapoints: [
...
                [9, 'water_current', {
                    from: (v) => (v * GALLON_TO_LITER / 1000).toFixed(1),
                    to: (v) => Math.round((parseFloat(v) / GALLON_TO_LITER) * 1000)
                }],
                [11, 'battery', tuya.valueConverter.raw],
...
            ],
        },
...

Not sure if this gonna work on GH

eerison commented 4 months ago

@OgV1 by default, the version of herdsman used by z2m only updates when z2m gets a new release. I believe you can switch z2m you can either switch zg2mqtt to use the 'dev' branch, which will make it keep herdsman up to date to the latest release: https://www.zigbee2mqtt.io/advanced/more/switch-to-dev-branch.html

Personally, I've been testing using a custom external definition (using these instructions, using an adapted version of the code from neo.ts in herdsman.

Hello guys,

Do you think this device will be available on the next release?

OgV1 commented 4 months ago

@OgV1 by default, the version of herdsman used by z2m only updates when z2m gets a new release. I believe you can switch z2m you can either switch zg2mqtt to use the 'dev' branch, which will make it keep herdsman up to date to the latest release: https://www.zigbee2mqtt.io/advanced/more/switch-to-dev-branch.html Personally, I've been testing using a custom external definition (using these instructions, using an adapted version of the code from neo.ts in herdsman.

Hello guys,

Do you think this device will be available on the next release?

Hi @eerison,

Unfortunately I don't think we will, as I found the difficulties in findings the working exposes that can work with all of correct data-points, I will be happy if I could get some help from someone who are more expert than me.

eerison commented 4 months ago

@OgV1 by default, the version of herdsman used by z2m only updates when z2m gets a new release. I believe you can switch z2m you can either switch zg2mqtt to use the 'dev' branch, which will make it keep herdsman up to date to the latest release: https://www.zigbee2mqtt.io/advanced/more/switch-to-dev-branch.html Personally, I've been testing using a custom external definition (using these instructions, using an adapted version of the code from neo.ts in herdsman.

Hello guys, Do you think this device will be available on the next release?

Hi @eerison,

Unfortunately I don't think we will, as I found the difficulties in findings the working exposes that can work with all of correct data-points, I will be happy if I could get some help from someone who are more expert than me.

Well I don't have any idea hehehe, But I just ordered this device and when it arrives I will try to help 🤞🏼

Thank you for reply <3

eerison commented 4 months ago

hey guys

maybe you could open a PR with the current code state, then it could help others to test or help somehow.

xpavli44 commented 4 months ago

@eerison that's been done ... you can use https://github.com/Koenkk/zigbee-herdsman-converters/pull/7630/files to create external converter as per https://www.zigbee2mqtt.io/advanced/support-new-devices/01_support_new_devices.html#_2-2-adding-converter-s-for-your-device

eerison commented 4 months ago

@eerison that's been done ... you can use https://github.com/Koenkk/zigbee-herdsman-converters/pull/7630/files to create external converter as per https://www.zigbee2mqtt.io/advanced/support-new-devices/01_support_new_devices.html#_2-2-adding-converter-s-for-your-device

ahhh I just found it: https://www.zigbee2mqtt.io/devices/NAS-WV03B.html

the image looks a bit different of the original post 😄

well if the integration is done, I guess this issue could be closed, couldn't it?

xpavli44 commented 4 months ago

@eerison I would not close it yet.

  1. It is still quirky, it works but it is throwing errors on button press etc. (read in above posts)
  2. It also does not load the image in z2m so it needs some love as well
eerison commented 4 months ago

@eerison I would not close it yet.

  1. It is still quirky, it works but it is throwing errors on button press etc. (read in above posts)
  2. It also does not load the image in z2m so it needs some love as well

thank you for clarify.

OgV1 commented 4 months ago

I just don't understand why my Water total and Single watering amount keeps showing 0 since the Water current is working, any ideas guys?

image image

eerison commented 4 months ago

Hello Guys.

my Sprinkler finally arrived :),

I am doing some tests and what works is just turn on and off using

{"state": "ON"}

but no water flow then I tried to activate this flow_switch

using

{"flow_switch": "ON"}

But I am getting this error

z2m: No converter available for 'flow_switch' ("ON")

I don't know if you faced the same issue ...

I didn't check yet how to debug it, I guess I can get this info here: https://www.zigbee2mqtt.io/advanced/support-new-devices/01_support_new_devices.html#_2-2-adding-converter-s-for-your-device (as @xpavli44 mentioned), But in case you have some tips how I could debug it "easily", I would appreciate any help :)

eerison commented 4 months ago

@OgV1 by default, the version of herdsman used by z2m only updates when z2m gets a new release. I believe you can switch z2m you can either switch zg2mqtt to use the 'dev' branch, which will make it keep herdsman up to date to the latest release: https://www.zigbee2mqtt.io/advanced/more/switch-to-dev-branch.html

Personally, I've been testing using a custom external definition (using these instructions, using an adapted version of the code from neo.ts in herdsman.

Hey @oliverwoodings

could you give me some idea how to tests using neo.ts

when I click on generate_external_definition just appear this piece of code Screenshot from 2024-07-20 18-22-40

But I can't click on read/write button, am I missing something?

OgV1 commented 4 months ago

@OgV1 by default, the version of herdsman used by z2m only updates when z2m gets a new release. I believe you can switch z2m you can either switch zg2mqtt to use the 'dev' branch, which will make it keep herdsman up to date to the latest release: https://www.zigbee2mqtt.io/advanced/more/switch-to-dev-branch.html Personally, I've been testing using a custom external definition (using these instructions, using an adapted version of the code from neo.ts in herdsman.

Hey @oliverwoodings

could you give me some idea how to tests using neo.ts

when I click on generate_external_definition just appear this piece of code Screenshot from 2024-07-20 18-22-40

But I can't click on read/write button, am I missing something?

@eerison My man, you definitely need to enable the debug for this

mine was first place the code in neo.ts and named to something like .js (I'm using spk.js (for sprinkler, duh!) in CONFIG/zigbee2mqtt image

then set your configuration.yaml as this instruction image

mine was like this image

after restart zb2mqtt the device will be ready to add (you may need to check if your device's fingerprint is matching these? fingerprint: tuya.fingerprint('TS0601', ['_TZE204_rzrrjkz2', '_TZE204_uab532m0']),

eerison commented 4 months ago

Thank you @OgV1 <3, I will give a try today

eerison commented 4 months ago

hey @OgV1

Could you post your spk.js code here please, it will be easier to test

OgV1 commented 4 months ago

hey @OgV1

Could you post your spk.js code here please, it will be easier to test

Yeah man feel free to try

edit: I'm not sure if the code will work, please try attached. spk.zip

eerison commented 4 months ago

just to be easy to copy and past in case someone else wants to test your code :)

const {} = require('zigbee-herdsman-converters/lib/modernExtend');
const fz = require('zigbee-herdsman-converters/converters/fromZigbee');
const tz = require('zigbee-herdsman-converters/converters/toZigbee');
const exposes = require('zigbee-herdsman-converters/lib/exposes');
const reporting = require('zigbee-herdsman-converters/lib/reporting');
const modernExtend = require('zigbee-herdsman-converters/lib/modernExtend');
const e = exposes.presets;
const ea = exposes.access;
const tuya = require('zigbee-herdsman-converters/lib/tuya');
const GALLON_TO_LITER = 3.78541;

const definition = {
        fingerprint: tuya.fingerprint('TS0601', ['_TZE204_rzrrjkz2', '_TZE204_uab532m0']),
        zigbeeModel: ['NAS-WV03B'],
        model: 'NAS-WV03B',
        vendor: 'Neo',
        fromZigbee: [tuya.fz.datapoints],
        toZigbee: [tuya.tz.datapoints],
        description: 'Smart sprinkler timer',
        onEvent: tuya.onEventSetTime,
        configure: tuya.configureMagicPacket,
        exposes: [
            e.binary('state', ea.STATE_SET, 'ON', 'OFF').withDescription('Turn the valve On or Off'),
            e.enum('status', ea.STATE, ['0', '1', '2', '3']).withDescription('Status'),
            e.numeric('countdown', ea.STATE_SET).withUnit('min').withValueMin(1).withValueMax(240).withDescription('Countdown'),
            e.numeric('countdown_left', ea.STATE).withUnit('min').withValueMin(1).withValueMax(240).withDescription('Countdown left'),
            e.numeric('water_current', ea.STATE).withUnit('L/min').withValueMin(0).withValueMax(3785.41).withValueStep(0.1)
                .withDescription('Current water flow (L/min)'), // Changed to liters
            e.battery(),
            e.numeric('water_total', ea.STATE).withUnit('L').withValueMin(0).withValueMax(378541.0).withValueStep(0.001)
                .withDescription('Total water flow (L)'), // Changed to liters
            e.binary('fault', ea.STATE, 'DETECTED', 'NOT_DETECTED').withDescription('Fault status'),
            e.enum('weather_delay', ea.STATE_SET, ['24h', '48h', '72h', 'cancel']).withDescription('Weather delay'),
            e.text('normal_timer', ea.STATE_SET).withDescription('Normal timer'),
            e.binary('switch_enabled', ea.STATE_SET, 'ON', 'OFF').withDescription('Switch enabled'),
            e.numeric('smart_irrigation', ea.STATE).withDescription('Smart irrigation'),
            e.binary('total_flow_reset_switch', ea.STATE_SET, 'ON', 'OFF').withDescription('Total flow reset switch'),
            e.numeric('quantitative_watering', ea.STATE_SET).withUnit('L').withValueMin(0).withValueMax(10000)
                .withDescription('Quantitative watering'), // Changed to liters
            e.binary('flow_switch', ea.STATE_SET, 'ON', 'OFF').withDescription('Flow switch'),
            e.binary('child_lock', ea.STATE_SET, 'ON', 'OFF').withDescription('Child lock'),
            e.numeric('surplus_flow', ea.STATE).withDescription('Surplus flow'),
            e.numeric('single_watering_duration', ea.STATE).withDescription('Single watering duration'),
            e.numeric('single_watering_amount', ea.STATE).withDescription('Single watering amount'),
        ],
        meta: {
            tuyaDatapoints: [
                [1, 'state', tuya.valueConverter.onOff],
                [3, 'status', tuya.valueConverterBasic.lookup({'Off': 0, 'one': 1, 'Child lock activated': 2, 'On': 3, 'On_btn': 4})],
                [5, 'countdown', tuya.valueConverter.raw],
                [6, 'countdown_left', tuya.valueConverter.raw],
                [9, 'water_current', {
                    from: (v) => {
                        convertedValue = (v * GALLON_TO_LITER / 1000).toFixed(1); // Converts the raw value from gal/min to L/min with one decimal place
                        console.log(`Raw value for water_current: ${v}, Converted value: ${convertedValue}`);
                        return convertedValue;
                    },
                    to: (v) => {
                        const rawValue = Math.round((parseFloat(v) / GALLON_TO_LITER) * 1000); // Converts L/min back to the raw value in gal/min
                        console.log(`Raw value for water_current: ${v}, Raw value: ${rawValue}`);
                        return rawValue;
                    },
                }],
                [11, 'battery', tuya.valueConverter.raw],
                [15, 'water_total', {
                    from: (v) => (v * GALLON_TO_LITER / 1000).toFixed(1), // Converts the raw value from gallons to liters with one decimal place
                    to: (v) => Math.round((parseFloat(v) / GALLON_TO_LITER) * 1000) // Converts liters back to the raw value in gallons
                }],
                [19, 'fault', tuya.valueConverter.raw],
                [37, 'weather_delay', tuya.valueConverter.raw],
                [38, 'normal_timer', tuya.valueConverter.raw],
                [42, 'switch_enabled', tuya.valueConverter.onOff],
                [47, 'smart_irrigation', tuya.valueConverter.raw],
                [101, 'total_flow_reset_switch', tuya.valueConverter.onOff],
                [102, 'quantitative_watering', {
                    from: (v) => (v * GALLON_TO_LITER / 1000).toFixed(1), // Converts the raw value from gallons to liters with one decimal place
                    to: (v) => Math.round((parseFloat(v) / GALLON_TO_LITER) * 1000) // Converts liters back to the raw value in gallons
                }],
                [103, 'flow_switch', tuya.valueConverter.onOff],
                [104, 'child_lock', tuya.valueConverter.onOff],
                [105, 'surplus_flow', tuya.valueConverter.raw],
                [106, 'single_watering_duration', tuya.valueConverter.raw],
                [108, 'single_watering_amount', {
                    from: (v) => {
                        const convertedValue = (v * GALLON_TO_LITER / 1000).toFixed(1);
                        console.log(`Raw value for single_watering_amount: ${v}, Converted value: ${convertedValue}`);
                        return convertedValue;
                    },
                    to: (v) => {
                        const rawValue = Math.round((parseFloat(v) / GALLON_TO_LITER) * 1000);
                        console.log(`Value to be sent for single_watering_amount: ${v}, Raw value: ${rawValue}`);
                        return rawValue;
                    }
                }],
            ],
        },
};

module.exports = definition;
eerison commented 3 months ago

Hey @OgV1

what did you enabled to see the console.log ? I have log_level: debug, But I don't see any console log :(

mpavlikWandera commented 3 months ago

@eerison you need to go Settings -> System -> Logs -> pick Z2M addon in upper right corner

eerison commented 3 months ago

The problem isn't visualize the log, the problem is, the console.log that I added into the definition, it isn't appearing

Screenshot_20240730_142711_Chrome

I added console.log here

                [103, 'flow_switch', {
                        from: (v) => {
                                console.log(`debug: [from] flow switch original value ${v}`)
                                return v;
                        },
                        to: (v) => {
                                console.log(`debug: [to] flow switch original value ${v}`)
                                return v;
                        }
                }],

but when I change the status, it isn't appearing :/

eerison commented 3 months ago

well I could get some progress at lest 😄

I tested console.debug on state and status field, and both I could see a log, But not with flow_switch, I belive it is happening because this error is happening before go into the from and to scope

[2024-07-30 10:57:12] debug:    z2m:mqtt: Received MQTT message on 'zigbee2mqtt/sprinkler_01/set' with data '{"flow_switch":"ON"}'
[2024-07-30 10:57:12] error:    z2m: No converter available for 'flow_switch' ("ON")

what this no converter available means? because there is a converter to on/off :/

eerison commented 3 months ago

@OgV1 how do you know those fields are correct?

{
    "battery": 67,
    "child_lock": "OFF",
    "countdown": 4,
    "countdown_left": 0,
    "linkquality": 116,
    "quantitative_watering": "0.0",
    "single_watering_amount": "0.0",
    "single_watering_duration": 0,
    "state": "OFF",
    "status": "Off",
    "water_current": "0.0",
    "water_total": "0.0",
    "fault": null,
    "flow_switch": null,
    "normal_timer": null,
    "smart_irrigation": null,
    "surplus_flow": null,
    "switch_enabled": null,
    "total_flow_reset_switch": null,
    "weather_delay": null
}

did you use Tuya Iot Platform? https://www.zigbee2mqtt.io/advanced/support-new-devices/03_find_tuya_data_points.html

eerison commented 3 months ago

I have the same valve and have found the tuya end point : {"1":"Switch", boolean "3":"Status", "type": "Enum", "values": "{"range":["off","auto","disabled"]}" "5":"Countdown", "type": "Integer", "values": "{"unit":"min","min":1,"max":240,"scale":0,"step":1}" "6":"Countdown Left", "type": "Integer", "values": "{"unit":"min","min":1,"max":240,"scale":0,"step":1}" "9":"Water Current" "type": "Integer", "values": "{"unit":"gal/min","min":0,"max":1000000000,"scale":3,"step":1}" "11":"Battery Percentage" "type": "Integer", "values": "{"unit":"%","min":0,"max":100,"scale":0,"step":1}" "15":"Water Total" "type": "Integer", "values": "{"unit":"gal","min":0,"max":999999999,"scale":3,"step":1}" "19":"Fault" "37":"Weather Delay", type enum {"range":["24h","48h","72h","cancel"]}" "38":"Normal Timer", "type": "String", "values": "{"maxlen":255}" "42":"Switch", boolean "47":"Smart Irrigation" "101":"Total flow reset switch", "102":"Quantitative watering", "103":"Flow switch"} "104":"Child lock" "105":"Surplus flow" "106":"Single watering time" "107":"Interface refresh", "108":"Amount of watering per time"}

I don't know to write the converter and need help

@dominique6017 are you sure that Flow switch doesn't have any type? because on your schema Child lock doesn't have any type, but it is a boolean (well it works as a boolean hehe)

baggiowu commented 3 months ago

ohhh .... it seems it may already exist? https://github.com/Koenkk/zigbee-herdsman-converters/blob/da65b1aeffd96527df02725b49de61e453fee059/src/devices/neo.ts#L130 just needs some tweaking?

Hi Guys,

I have created that converter based on this fingerprint _TZE204_rzrrjkz2 in this pull request

And actually not sure if I did it right, because I still don't have a chance to test with my own device (Guess it because the fingerprint is now _TZE204_uab532m0 and not the same as mine _TZE204_rzrrjkz2?)

Anyone have any idea how to solve this? and why do we have different fingerprints on the same device?

edit: Somehow, mine was slightly different with no Neo logo on it, is there any chances that it not actually Neo's ? image

FYI this is the info from my vendor: he seems to be sure that this one is Neo's with model number NAS-WV03B

_TZE204_uab532m0 its unit is Imperial gallons. _TZE204_rzrrjkz2 its unit is US gallons. Their model is 'NAS-WV05B2'.

eerison commented 3 months ago

ohhh .... it seems it may already exist? https://github.com/Koenkk/zigbee-herdsman-converters/blob/da65b1aeffd96527df02725b49de61e453fee059/src/devices/neo.ts#L130 just needs some tweaking?

Hi Guys, I have created that converter based on this fingerprint _TZE204_rzrrjkz2 in this pull request And actually not sure if I did it right, because I still don't have a chance to test with my own device (Guess it because the fingerprint is now _TZE204_uab532m0 and not the same as mine _TZE204_rzrrjkz2?) Anyone have any idea how to solve this? and why do we have different fingerprints on the same device? edit: Somehow, mine was slightly different with no Neo logo on it, is there any chances that it not actually Neo's ? image FYI this is the info from my vendor: he seems to be sure that this one is Neo's with model number NAS-WV03B

_TZE204_uab532m0 its unit is Imperial gallons. _TZE204_rzrrjkz2 its unit is US gallons. Their model is 'NAS-WV05B2'.

Yep I also saw the model was wrong :/

I am looking forward to see your PR merged 🤞🏼

OgV1 commented 3 months ago

@OgV1 how do you know those fields are correct?

{
    "battery": 67,
    "child_lock": "OFF",
    "countdown": 4,
    "countdown_left": 0,
    "linkquality": 116,
    "quantitative_watering": "0.0",
    "single_watering_amount": "0.0",
    "single_watering_duration": 0,
    "state": "OFF",
    "status": "Off",
    "water_current": "0.0",
    "water_total": "0.0",
    "fault": null,
    "flow_switch": null,
    "normal_timer": null,
    "smart_irrigation": null,
    "surplus_flow": null,
    "switch_enabled": null,
    "total_flow_reset_switch": null,
    "weather_delay": null
}

did you use Tuya Iot Platform? https://www.zigbee2mqtt.io/advanced/support-new-devices/03_find_tuya_data_points.html

Hi @eerison

Yes, I use the same method in that link (The Automatic method on step 8.) image

eerison commented 3 months ago

The PR from @baggiowu was closed :(

Could you send here the debug page, then I could see the fields and types.

like this one:

Screenshot 2024-08-02 at 09 27 06

also the request please :) https://www.zigbee2mqtt.io/advanced/support-new-devices/03_find_tuya_data_points.html#_8-find-your-data-point

Note: this screenshot is from a wifi device that I have, as I don't have an getaway tuya I can't test the sprinkler :(

Edit: maybe it was fixed on this PR: https://github.com/Koenkk/zigbee-herdsman-converters/pull/7812 Edit 2: It was released on https://github.com/Koenkk/zigbee-herdsman-converters/releases/tag/v19.72.0

OgV1 commented 3 months ago

Try this

Standard Status Set Code Type Values switch Boolean "{true,false}" status Enum
{ "range": [ "off", "auto", "disabled" ] } countdown Integer { "unit": "min", "min": 1, "max": 240, "scale": 0, "step": 1 } countdown_left Integer { "unit": "min", "min": 1, "max": 240, "scale": 0, "step": 1 } water_current Integer { "unit": "gal/min", "min": 0, "max": 1000000000, "scale": 3, "step": 1 } battery_percentage Integer { "unit": "%", "min": 0, "max": 100, "scale": 0, "step": 1 } water_total Integer { "unit": "gal", "min": 0, "max": 999999999, "scale": 3, "step": 1 } weather_delay Enum
{ "range": [ "24h", "48h", "72h", "cancel" ] } normal_timer String
{ "maxlen": 255 } weather_switch Boolean "{true,false}" switch_enabled Boolean "{true,false}"

OgV1 commented 3 months ago

After I tried with @baggiowu version released, there looks like I still get some errors

  1. the water total is keeps showing 0
  2. the flow switch and total flow switch will reported 'no converter' when I turned them ON of OFF image
wifijt commented 3 months ago

I have been playing with this code for the last few days - I can't get the battery to show at all. I have a Tuya account and went in and looked at the code - it says it's 11 and when connected to the Tuya cloud it reports as 100%. I have gone back and forth with the e.battery() vs e.numeric(..) and the raw vs batterypercentage to no affect.

Is there a way in debug to see the report from the device? or does the topic have to be created with the correct data points for it to be published?

My product name in Tuya is Zigbee 05浇灌开关 E版本 美制单位gal

Which translates to Zigbee 05 watering switch E version American unit gal

Here is my code just in case I've made a stupid mistake: `const fz = require('zigbee-herdsman-converters/converters/fromZigbee'); const tz = require('zigbee-herdsman-converters/converters/toZigbee'); const exposes = require('zigbee-herdsman-converters/lib/exposes'); const reporting = require('zigbee-herdsman-converters/lib/reporting'); const modernExtend = require('zigbee-herdsman-converters/lib/modernExtend'); const e = exposes.presets; const ea = exposes.access; const tuya = require('zigbee-herdsman-converters/lib/tuya');

const definition = { fingerprint: tuya.fingerprint('TS0601', ['_TZE204_rzrrjkz2', '_TZE204_uab532m0']), zigbeeModel: ['NAS-WV03B'], model: 'NAS-WV03B', vendor: 'Neo', fromZigbee: [tuya.fz.datapoints], toZigbee: [tuya.tz.datapoints], description: 'Smart sprinkler timerzz', onEvent: tuya.onEventSetTime, configure: tuya.configureMagicPacket, exposes: [ e.switch(), e.enum('status', ea.STATE, ['off', 'auto', 'disabled', 'app_manual', 'key_control']).withDescription('Status'), e.numeric('countdown', ea.STATE_SET).withUnit('min').withValueMin(1).withValueMax(240).withDescription('Countdown'), e.numeric('countdown_left', ea.STATE).withUnit('min').withValueMin(1).withValueMax(240).withDescription('Countdown left'), e .numeric('water_current', ea.STATE) .withUnit('gal/min') .withValueMin(0) .withValueMax(3785.41) .withValueStep(0.001) .withDescription('Current water flow (L/min)'), e.numeric('battery_percentage', ea.STATE).withUnit('%').withValueMin(0).withValueMax(100).withDescription('Battery percentage'), e .numeric('water_total', ea.STATE) .withUnit('G') .withValueMin(0) .withValueMax(378541.0) .withValueStep(0.001) .withDescription('Total water flow (G)'), e.binary('fault', ea.STATE, 'DETECTED', 'NOT_DETECTED').withDescription('Fault status'), e.enum('weather_delay', ea.STATE_SET, ['24h', '48h', '72h', 'cancel']).withDescription('Weather delay'), e.text('normal_timer', ea.STATE_SET).withDescription('Normal timer'), e.binary('switch_enabled', ea.STATE_SET, 'ON', 'OFF').withDescription('Switch enabled'), e.numeric('smart_irrigation', ea.STATE).withDescription('Smart irrigation'), e.binary('total_flow_reset_switch', ea.STATE_SET, 'ON', 'OFF').withDescription('Total flow reset switch'), e .numeric('quantitative_watering', ea.STATE_SET) .withUnit('G') .withValueMin(0) .withValueMax(10000) .withDescription('Quantitative watering'), e.binary('flow_switch', ea.STATE_SET, 'ON', 'OFF').withDescription('Flow switch'), e.binary('child_lock', ea.STATE_SET, 'ON', 'OFF').withDescription('Child lock'), e.numeric('surplus_flow', ea.STATE).withDescription('Surplus flow'), e.numeric('single_watering_duration', ea.STATE).withDescription('Single watering duration'), e.numeric('single_watering_amount', ea.STATE).withDescription('Single watering amount'), ], meta: { tuyaDatapoints: [ [1, 'state', tuya.valueConverter.onOff], [ 3, 'status', tuya.valueConverterBasic.lookup({ off: tuya.enum(0), auto: tuya.enum(1), disabled: tuya.enum(2), app_manual: tuya.enum(3), key_control: tuya.enum(4), }), ], [109, 'countdown', tuya.valueConverter.raw], [6, 'countdown_left', tuya.valueConverter.raw], [9, 'water_current', tuya.valueConverter.raw], [11, 'battery_percentage', tuya.valueConverter.raw], [15, 'water_total', tuya.valueConverter.raw], [19, 'fault', tuya.valueConverter.raw], [37, 'weather_delay', tuya.valueConverter.raw], [38, 'normal_timer', tuya.valueConverter.raw], [42, 'switch_enabled', tuya.valueConverter.onOff], [47, 'smart_irrigation', tuya.valueConverter.raw], [101, 'total_flow_reset_switch', tuya.valueConverter.onOff], [102, 'quantitative_watering', tuya.valueConverter.raw], [103, 'flow_switch', tuya.valueConverter.onOff], [104, 'child_lock', tuya.valueConverter.onOff], [105, 'surplus_flow', tuya.valueConverter.raw], [106, 'single_watering_duration', tuya.valueConverter.raw], [108, 'single_watering_amount', tuya.valueConverter.raw], ], },

};

module.exports = definition; `

eerison commented 3 months ago

Yeah I also tested @baggiowu implementation, but it didn't work 😕

well nothing worked, even turn on/off :(

eerison commented 3 months ago

Hey @OgV1 I saw that @baggiowu added different models, which model appeared for you?

NAS-WV03B?

eerison commented 3 months ago

ohhh .... it seems it may already exist? https://github.com/Koenkk/zigbee-herdsman-converters/blob/da65b1aeffd96527df02725b49de61e453fee059/src/devices/neo.ts#L130 just needs some tweaking?

Hi Guys, I have created that converter based on this fingerprint _TZE204_rzrrjkz2 in this pull request And actually not sure if I did it right, because I still don't have a chance to test with my own device (Guess it because the fingerprint is now _TZE204_uab532m0 and not the same as mine _TZE204_rzrrjkz2?) Anyone have any idea how to solve this? and why do we have different fingerprints on the same device? edit: Somehow, mine was slightly different with no Neo logo on it, is there any chances that it not actually Neo's ? image FYI this is the info from my vendor: he seems to be sure that this one is Neo's with model number NAS-WV03B

_TZE204_uab532m0 its unit is Imperial gallons. _TZE204_rzrrjkz2 its unit is US gallons. Their model is 'NAS-WV05B2'.

I think the problem is , we are still taking the old model, I guess it should be NAS-WV05B2 as mentioned by @baggiowu. But I don't know why it is still the old one NAS-WV03B

andrewcfitz commented 2 months ago

And I found another weird behavior. Looks like after we press the button, (doesn't matter remotely or physical) the device will switch off by itself after around 30 seconds, the reason is might because that there is no water through the valve, I have to test. Edit: Alright, I have tested, doesn't stop by itself, there is nothing to worry about this.