LCSB-BioCore / COBREXA.jl

Constraint-Based Reconstruction and EXascale Analysis
https://lcsb-biocore.github.io/COBREXA.jl/
Apache License 2.0
42 stars 8 forks source link

FVA does not include optimization problem modifications #219

Closed stelmo closed 3 years ago

stelmo commented 3 years ago

Currently flux_variability_analysis does not apply problem modifications to the flux min/max sub-problems after FBA has been applied. This means that the user might specify certain modifications that affect the objective value but these constraints are not applied when finding the actual variability.

exaexa commented 3 years ago

Closed by #275

exaexa commented 3 years ago

:tada: