Closed LeonardSchmiester closed 4 years ago
Model parameter 'init_b10' present in both condition table and parameter table.
ping
I hope I fixed it. Will check when condition specific parameters issues in PEtab are fixed.
experimentalCondition file experimentalCondition_Bruno_JExpBio2016
has a column for init_b10_1
with assignment init_b10
. I believe this should be the other way around, we want the model parameter init_b10
to be fitted with fit item init_b10_
for experimental condition1
Should be fixed by #77
the sigma parameters are missing in the SBML