Hi

When calling command "CalibrateImage" For freq 868Mhz , Base on datasheet, this Number should be 0xDB , but in SX126x.c, this code is 0xD8 image image

Which one is correct ? I think the correct one is in Datasheet. DB.

mluis1 commented 5 years ago

Value 0xDB is the correct value. We will provide a fix as soon as possible.