vikasrohal commented 2 years ago

Hi, I'm testing a SX1302 + SX1250 based gateway with 5dBm o/p LoRa device 20 dB Attenuator is connected between LoRa device and Gateway (This is conducted test) I'm getting -3dBm signal on feeding point of SX1250 pin(RFI pin , measured by spectrum Analyzer) but packet forwader showing received RSSI is -33. Why that much deviation? I did the same with sx1301 + sx1257 based gateway, its showing accepted results (-3dB received and showing near about -3 received RSSI)

vikasrohal commented 2 years ago

Thats was a testing issue

mjlaurent6 commented 1 year ago

Hi can you share more about your experience ? I am having the issue on Sx1302 that receive very low rssi

saffetblt commented 10 months ago

Hello, I have a similar problem. I can't get more than -115 rssi with a gateway with SX1302. I have an external commercial gateway. But it can catch even -138 rssi values. Do you have any idea?