Missing Data #3

Closed Timeofsand closed 1 year ago

Timeofsand commented 1 year ago

Hello, everyone.

I installed the project and it was relatively easy to set up. However, I don't know exactly how to proceed because I don't know that much about Modbus.

My problem is I don't have all the data I would like in Node-Red. I miss the current power. Here is an example of what I get:

My Output pvstatus: 9 pvpowerin: 0 pv1voltage: 0 pv1current: 0 pv1watt: 0 pv2voltage: 0 pv2current: 0 pv2watt: 0 pvpowerout: 0 pvfrequentie: 5001 pvgridvoltage: 4060 pvgridcurrent: 0 pvgridpower: 344 pvgridvoltage2: 4187 pvgridcurrent2: 0 pvgridpower2: 0 pvgridvoltage3: 4125 pvgridcurrent3: 0 pvgridpower3: 0 eactoday: 28 pvenergytoday: 28 eactotal: 162 totworktime: 579968 epv1today: 36 epv1total: 194 epv2today: 0 epv2total: 0 epvtotal: 194 pvtemperature: 255 pvipmtemperature: 237 pvboosttemp: 235 bat_dsp: 11 eacharge_today: 2 eacharge_total: 7 batterytype: 1 uwsysworkmode: 9 systemfaultword0: 0 systemfaultword1: 0 systemfaultword2: 0 systemfaultword3: 33348 systemfaultword4: 32 systemfaultword5: 0 systemfaultword6: 0 systemfaultword7: 0 pdischarge1: 0 p1charge1: 0 vbat: 0 SOC: 0 pactouserr: 3800 pactousertot: 3800 pactogridr: 0 pactogridtot: 0 plocaloadr: 3800 plocaloadtot: 3800 spdspstatus: 9 spbusvolt: 38 etouser_tod: 99 etouser_tot: 477 etogrid_tod: 14 etogrid_tot: 47 edischarge1_tod: 0 edischarge1_tot: 0 eharge1_tod: 0 eharge1_tot: 0 elocalload_tod: 117 elocalload_tot: 611 datalogserial: "ModBus2USB" pvserial: "TJJ4CG300D"

I use the GROWATT SPH 4000TL3 BRA-UP

Thank You

Lyve1981 commented 1 year ago

I see you just closed it, but for others for future reference: pvstatus: 9 indicates that the inverter is running in Bypass mode