We can look at this closer, control systems can typically have sensor
measurements much faster than PID. PID was offset from sensor measurements to
not block whole loop. Let's examine to see if we really need to improve this.
Original comment by CaranchoEngineering@gmail.com
on 14 Feb 2011 at 8:08
Yes, sensors can (or even should?) be sampled in a higher frequency than PID is
called, but not the other way for example with the altitude hold. Then the
sensor is sampled in 20Hz (about) but calling PID for that sensor in 300Hz
(about). That can't be right. D term of barometer should correspond to m/s
(although noisy perhaps).