[BUG] the z probe do not compensate enough the bed level #17253

Closed rainito closed 4 years ago

rainito commented 4 years ago

Hi to all dear friend. I have a serious problem with my printer. I have an flsun with double extruder, inductive sensor for the autolevel and the zise of the biuld plate of 300 x 300 with glass plate. My problem is the probe leveling. I see the z stepper motor move to the right direction for compensate the bed level but don't move enouht.
 I have the right side of the bed with the nozzle too close to the bed and the left side with the nozzle too far from the bed. I try linear and bilinear mode but the problem is the same. I have two z motor axis and i have leveled every motor to have the same distance of the nozzle in the left and right side. I try with marlin 1.1.9x bugfix, marlin 2.0.x bugfix and an older version of marlin 1.1.4 but the problem always exist. I have an mks gen l like motherboard and for x-y and z axis the tmc2208 driver and for the extruders the lv8729 drivers.Sorry for my english but i’m italian-

Bug Description

The z probe do not compensate perfectly the level of the bed

I will update mi configuration h and adv when i will go home after work. Thanks to all

Steps to Reproduce

  1. G28 G29 Z0 and with a paper below the nozzle try the resistance. In the center is perfect but going to the left of the bed, the nozzle go down but not enought, so the nozzle stay too far from the bed and vice versa for the right side (the nozzle go up but not enought so the nozzle is too far to the bed) Expected behavior: The probe would compensate the level of the bed correctly.
rado79 commented 4 years ago

https://github.com/MarlinFirmware/Marlin/issues/15206

rainito commented 4 years ago

Hi and thanks for the reply. I've read that post but my axis are perfect. I haven't hardware problem or i think this. I checked all amd i don't find anything. The probel can be only by hardware?

rainito commented 4 years ago

Archivio.zip

thinkyhead commented 4 years ago

Whenever there are homing or leveling issues, we now ask everyone to follow a standard procedure to gather more information so that we're not just taking stabs in the dark. Here is the boilerplate:

Repeat this procedure, if needed, to demonstrate inconsistencies. From these logs we should hopefully get a better idea of what's going on with your machine.

thinkyhead commented 4 years ago

Since your mesh doesn't seem to be working for you, test under very controlled conditions with simple moves. Use M114 D to check the current position for leveling being applied. Observe your Z motors to see that they are turning as you do XY moves. You can also clear and then edit the mesh and do tests with a single value set to (for example) -0.2 or +0.2 to see that the nozzle raises or lowers as expected when it goes to that point.

Please collect as much data as possible to demonstrate incorrect behavior, and this will help to locate the problem, if any.

rainito commented 4 years ago

Hi and thanks to you too for the reply. Sorry for my late reply but i’m a nurse and in this period i’m very busy with the work and sorry for my English but i’m italian :) Today i will try your first tip and then the second and will let you knoe the tests results. Thanks and stay tuned :)

rainito commented 4 years ago

ok these are the results of the two attempts of your first tip. in the extreme left of the bed i have a perfect distance for the first layer but just as soon i move the x axis to the right the nozzle don't go up enough and the nozzle press the plate. i see the z axis motors moves to compensate but not enough 🤯 i see if i move the y axis the nozzle go up and down. In one point is perfect and in another points is too far or too close...i don’t know what i have to think.. asap i try your second tip and i will update the results. primo.pdf secondo.pdf

rainito commented 4 years ago

Since your mesh doesn't seem to be working for you, test under very controlled conditions with simple moves. Use M114 D to check the current position for leveling being applied. Observe your Z motors to see that they are turning as you do XY moves. You can also clear and then edit the mesh and do tests with a single value set to (for example) -0.2 or +0.2 to see that the nozzle raises or lowers as expected when it goes to that point.

Please collect as much data as possible to demonstrate incorrect behavior, and this will help to locate the problem, if any.

ok,how you can see,the levelling is working as you can see by m114 d but in the bed the nozzle is too far and in the right too close left side: SENDING:M114 D X:20.00 Y:180.00 Z:0.00 E:0.00 Count X:2000 Y:18000 Z:-74 Logical: X:20.000 Y:180.000 Z:0.000 Raw: X:20.000 Y:180.000 Z:0.000 Leveled: X:20.000 Y:180.000 Z:-0.185 UnLevel: X:20.000 Y:180.000 Z:0.000 Stepper: X:2000 Y:18000 Z:-74 E:0 FromStp: X:20.000 Y:180.000 Z:-0.185 E:0.000 Diff: X:0.000 Y:0.000 Z:-0.000 E:0.000

right side SENDING:M114 D X:270.00 Y:180.00 Z:0.00 E:0.00 Count X:27000 Y:18000 Z:60 Logical: X:270.000 Y:180.000 Z:0.000 Raw: X:270.000 Y:180.000 Z:0.000 Leveled: X:270.000 Y:180.000 Z:0.151 UnLevel: X:270.000 Y:180.000 Z:0.000 Stepper: X:27000 Y:18000 Z:60 E:0 FromStp: X:270.000 Y:180.000 Z:0.150 E:0.000 Diff: X:0.000 Y:0.000 Z:-0.001 E:0.000

i don't know what i need to do...can i change manually the mesh in every single problem points? if yes how can i do this?? is better the UBL sistem with my kind of problem? help

rainito commented 4 years ago

someone can help me??

rainito commented 4 years ago

Is it possible to invert the logic of the probe? it appears that the sensor regulates the height reversed. When it has to go down, it goes up and vice versa

rainito commented 4 years ago

I read in some post that can be a resistor problem in my board. I have an mks gen l v 1.0 and an lj18a3-8-z/bx npn no inductive sensor mounted. Can i post the link of that post? Is another forum

thinkyhead commented 4 years ago

For best results getting help with configuration and troubleshooting, please use the following resources:

After seeking help from the community, if the consensus points to a bug in Marlin, then you should post a bug report.

github-actions[bot] commented 4 years ago

This issue has been automatically locked since there has not been any recent activity after it was closed. Please open a new issue for related bugs.