[BUG] M122 S0 doesn't stop or prevent continuous debugging output #24372

Closed CBoismenu closed 2 years ago

CBoismenu commented 2 years ago

Did you test the latest bugfix-2.1.x code?

Yes, and the problem still exists.

Bug Description

[BUG] With TMC_DEBUG enabled in Configuration_adv.h using the M122 S0 command doesn't prevent continuous debugging from being trigered

Bug Timeline

Was also there in 2.0.9.3

Expected behavior

Expecting printer not to enter Continuous Debugging Mode.

Actual behavior

M122 S0 or M122 S1 produces the same output system enters Continuous Debugging Mode

Steps to Reproduce

Enable TMC_DEBUG in Configuration_adv.h

Compile and load the firmware

M122 S0 in Octoprint Terminal causes the following to be generated:

Send: M122 S0 Recv: axis:pwm_scale/curr_scale/mech_load|flags|warncount Recv: X Y Z Z2 E Recv: Address 0 0 Recv: Enabled false false true true false Recv: Set current 550 550 200 200 550 Recv: RMS current 520 520 183 183 520 Recv: MAX current 733 733 258 258 733 Recv: Run current 16/31 16/31 5/31 5/31 16/31 Recv: Hold current 8/31 8/31 2/31 2/31 8/31 Recv: CS actual 8/31 8/31 2/31 2/31 8/31 Recv: PWM scale Recv: vsense 1=.18 1=.18 1=.18 1=.18 1=.18 Recv: stealthChop true true true true true Recv: msteps 16 16 16 16 16 Recv: interp true true true true true Recv: tstep max max max max max Recv: PWM thresh. 98 98 98 98 188 Recv: [mm/s] 100 100 20 20 30 Recv: OT prewarn false false false false false Recv: triggered Recv: OTP false false false false false Recv: pwm scale sum 12 11 11 10 10 Recv: pwm scale auto 0 0 0 1 0 Recv: pwm offset auto 45 42 127 106 36 Recv: pwm grad auto 13 12 25 23 14 Recv: off time 4 4 4 4 4 Recv: blank time 24 24 24 24 24 Recv: hysteresis Recv: -end 2 2 2 2 2 Recv: -start 1 1 1 1 1 Recv: Stallguard thrs 60 60 Recv: uStep count 408 424 360 824 88 Recv: DRVSTATUS X Y Z Z2 E Recv: sg_result 60 110 Recv: stst Recv: olb Recv: ola Recv: s2gb Recv: s2ga Recv: otpw Recv: ot Recv: 157C Recv: 150C Recv: 143C Recv: 120C Recv: s2vsa Recv: s2vsb Recv: Driver registers: Recv: X 0xC0:08:00:00 Recv: Y 0xC0:08:00:00 Recv: Z 0xC0:02:00:00 Recv: Z2 0xC0:02:00:00 Recv: E 0xC0:08:00:00 Recv: Recv: Recv: Testing X connection... OK Recv: Testing Y connection... OK Recv: Testing Z connection... OK Recv: Testing Z2 connection... OK Recv: Testing E connection... OK Recv: ok Recv: X:12/8/-|TI| Y:11/8/-|TI| Z:11/2/-|TI| Z2:10/2/-|TI| E:10/8/-|TI| Recv: T:150.06 /150.00 B:60.00 /60.00 @:26 B@:0 Recv: Not SD printing Recv: X:12/8/-|TI| Y:11/8/-|TI| Z:11/2/-|TI| Z2:10/2/-|TI| E:10/8/-|TI| Recv: X:0.0000 Y:0.0000 Z:15.0000 E:0.0000 Count X:0 Y:0 Z:6023 Recv: X:12/8/-|GTI| Y:11/8/-|GTI| Z:11/2/-|GTI| Z2:10/2/-|GTI| E:10/8/-|GTI| Recv: Not SD printing Recv: X:12/8/-|TI| Y:11/8/-|TI| Z:11/2/-|TI| Z2:10/2/-|TI| E:10/8/-|TI|

Goes on continuously.

I can change the frequency with M122 P<> but canot stop it.

Version of Marlin Firmware

2.1

Printer model

Duplicator i3 plus

Electronics

SKR V1.3

Add-ons

BLTouch

Bed Leveling

ABL Bilinear mesh

Your Slicer

Prusa Slicer

Host Software

OctoPrint

Don't forget to include

Additional information & file uploads

Marlin.zip

parallyze commented 2 years ago

Can confirm this is happening in 2.1 release and bugfix from a few days ago. Setting the interval using P does work, turning off reporting using S0 doesn't. Will test up to date bugfix and provide configs if required.

Possibly connected to 25d5d2ab507075f282787c6e5c9d57f1a3972e1e

Changing the line const bool sflag = parser.seen_test('S'), sval = sflag && parser.value_bool(); to const bool sflag = parser.seen('S'), sval = sflag && parser.value_bool();

("parser.seen_test -> parser.seen") seems to work, S0/S1 does turn off/on reporting again, don't know what possible other effects this change might cause.

hcet14 commented 2 years ago

Latest bugfix-2.1.x (3 hours ago) same behavior, as stated in first post.

Changing the line const bool sflag = parser.seen_test('S'), sval = sflag && parser.value_bool(); to const bool sflag = parser.seen('S'), sval = sflag && parser.value_bool(); ("parser.seen_test -> parser.seen") seems to work, S0/S1 does turn off/on reporting again, don't know what possible other effects this change might cause.

Works here too, but for both versions: [BUG] sg_result on Y doesn't work. Constant 16.

I'll build a classical cartesian with 4 steppers. I changed the drivers, no difference. Right now, I have the mainboard with the 4 steppers connected on the bench. If you want me to do some tests, tell me.

CBoismenu commented 2 years ago

The proposed modification fixed the problem on my system.

I haven'seen any negative or unwanted effect at this point.

I'll keep you posted if I find anything wrong.

hcet14 commented 2 years ago

I haven'seen any negative or unwanted effect at this point.

Did you try sg_result and hold the steppers?

hcet14 commented 2 years ago

@CBoismenu

Did you read my question?

Did you try sg_result and hold the steppers?

CBoismenu commented 2 years ago

@hcet14

Did read your question.

Although I've been working on compiling the firmware for a while I didn't understand what you wanted me to try.

If you can give me more information I would be willing to try it out.

hcet14 commented 2 years ago

@CBoismenu

Sorry I was a little sick and then I had to work a lot, now ok.

Tried it with Marlin-bugfix-2.1.x_220807_17_52 from today:

M122 S0 or M122 S1 produces the same output system enters Continuous Debugging Mode

As you stated at the beginning, nothing changed!

I guess nobody of the developers noticed the bug. But you didn't mark this issue as a bug!

Although I've been working on compiling the firmware for a while I didn't understand what you wanted me to try. If you can give me more information I would be willing to try it out.

Please use M122 and look at these values, just an example (sg_result 206 16 58 86). Now, please hold/brake your y-axis and move it. Does the y-value changes? You have to use M122 again to read it out. Thanks in advance.

It's working on x, z, and e as expected. Mainboard is SKR 2 with TMC2209s and Cartesian printer. I swapped my TMC2209s around, but no difference. Y stays at 16! Maybe you may try y and tell me your results. SKR 2 has a lot of hardware bugs, maybe it's caused by the board.

Please edit your issue and put a big [BUG] in front of your bug summary! Good work!

oh, I forgot config_Marlin-bugfix-2.1.x_220807_17_52.zip

CBoismenu commented 2 years ago

Tried your request on two of my printers.

Configuration #1 SKR1.3 with TMC2209 on X and Y and TMC2208 on Z Z2 and E Before Y move: sg_result 60 16 After Y move while holding the bed: sg-result 60 62

Configuration #2 SKR2.0 with TMC2209 on all axis Before Y move: sg_result 0 142 0 0 0 After Y move while holding the bed: sg-result 0 42 0 0 0

Both boards are on Marlin 2.1 and are cartesian printers

hcet14 commented 2 years ago

@CBoismenu Thank you very much! Mmmh, mysterious. Which Marlin version did you use for your tests? bugfix-2.1.x from (date, time)? I would like to test the exact version you were using. Could you attach the 'Marlin-bugfix-2.1.x.zip' you used?

CBoismenu commented 2 years ago

Marlin version was 2.1 for both boards

hcet14 commented 2 years ago

@CBoismenu

I'm terribly sorry that I stole your time! Thank you very much!

I thought my SKR 2 had a bug, but no. Just my missing knowledge about Marlin and TMCs.

I should have tried both directions from the beginning ;)

This is my setup IMG_20220815_203401

I used Marlin-2.1.1 from 220806.

M122 results: sg_result 0 0 0 0 after reboot, no stepper moved yet sg_result 210 0 0 0 x to one direction sg_result 16 0 0 0 x to the other direction sg_result 16 212 0 0 y to one direction sg_result 16 16 0 0 y to the other direction sg_result 16 16 58 0 z to one direction sg_result 16 16 70 0 z to the other direction sg_result 16 16 70 88 e to one direction sg_result 16 16 70 16 e to the other direction

Funny behaviour of z. But I don't care.

Thanks a lot. I read the TMC datasheet back and forth and didn't understand the behaviour.

I asked here 'https://reprap.org/forum/read.php?415,890279' and here 'https://github.com/bigtreetech/SKR-2/issues/164'.

But with this version of Marlin, that I tried M122 S0 behaves like M122 S1. There is no continuous debugging. It just runs once.

hcet14 commented 2 years ago

Latest bugfix-2.1.x (5 hours ago) different behavior, as stated in first post. When you use M122 S0 or M122 S1, it runs forever until reset of the mainboard. Using M122 runs the command once. I compared the files in /Marlin/scr/gcode/feature/trinamic from bugfix-2.1.x (5 hours ago) with Marlin-2.1.1 from 220806. No difference. Playing with define HYBRID_THRESHOLD and define MONITOR_DRIVER_STATUS also no change.

Why do bugfix-2.1.x (5 hours ago) and Marlin-2.1.1 from 220806 behave different?

github-actions[bot] commented 2 years ago

This issue has had no activity in the last 60 days. Please add a reply if you want to keep this issue active, otherwise it will be automatically closed within 10 days.

github-actions[bot] commented 1 year ago

This issue has been automatically locked since there has not been any recent activity after it was closed. Please open a new issue for related bugs.