Open nvx opened 11 months ago
The mqtt data contains smart meter data, but there are no entities for it.
device_type_code: SG5K-D run_state: 'ON' protocol_number: 1095905280 protocol_version: 16781824 arm_software_version: 0 dsp_software_version: 0 serial_number: 16690 nominal_active_power: 5 output_type: 2P daily_power_yields: 13.7 total_power_yields: 29074.1 total_running_time: 25566 internal_temperature: 61.6 total_apparent_power: 0 mppt_1_voltage: 220.2 mppt_1_current: 9.6 mppt_2_voltage: 349.9 mppt_2_current: 8.8 mppt_3_voltage: 0 mppt_3_current: 0 total_dc_power: 5221 phase_a_voltage: 250.7 phase_b_voltage: 0 phase_c_voltage: 0 phase_a_current: 20 phase_b_current: 0 phase_c_current: 0 total_active_power: 5013 total_reactive_power: 214 power_factor: 1 grid_frequency: 50.02 work_state_1: Run alarm_code_1: 0 nominal_reactive_power: 1.5 array_insulation_resistance: 1089 active_power_regulation_setpoint: 0 reactive_power_regulation_setpoint: 0 work_state_2: Stop meter_power: -3784 meter_a_phase_power: 0 meter_b_phase_power: 0 meter_c_phase_power: 0 load_power: 1229 daily_export_energy: 9.1 total_export_energy: 22945 daily_import_energy: 4.9 total_import_energy: 9949.2 daily_direct_energy_consumption: 4.6 total_direct_energy_consumption: 6129.1 daily_running_time: 675 mppt_4_voltage: 0 mppt_4_current: 0 mppt_5_voltage: 0 mppt_5_current: 0 mppt_6_voltage: 0 mppt_6_current: 0 mppt_7_voltage: 0 mppt_7_current: 0 mppt_8_voltage: 0 mppt_8_current: 0 monthly_power_yields: 0 mppt_9_voltage: 0 mppt_9_current: 0 mppt_10_voltage: 0 mppt_10_current: 0 mppt_11_voltage: 0 mppt_11_current: 0 mppt_12_voltage: 0 mppt_12_current: 0 negative_voltage_to_the_ground: 0 bus_voltage: 0 pid_work_state: 0 pid_alarm_code: 0 export_power: 0 power_meter: 0 pv_power_of_today: 5 daily_pv_energy_yields: 30.9 monthly_pv_energy_yields: 883 yearly_pv_energy_yields: 1310.4 direct_power_consumption_today_pv: 0 start_stop: Start power_limitation_switch: Enable power_limitation_setting: 100 export_power_limitation: Disable export_power_limitation_value: 500 current_transformer_output_current: 0 current_transformer_range: 0 current_transformer: 0 export_power_limitation_percentage: 100 installed_pv_power: 0 power_factor_setting: 1 night_svg_switch: 0 reactive_power_adjustment_mode: 'Off' reactive_power_percentage_setting: 0 power_limitation_adjustment: 0 reactive_power_adjustment: 0 pid_recovery: 0 anti_pid: 0 fullday_pid_suppression: 0 export_to_grid: 3784
For example there is no entity with the total_export_energy or total_import_energy. The only energy entity is the inverter daily generation entity.
total_export_energy
total_import_energy
Using the HassOS Addon
The mqtt data contains smart meter data, but there are no entities for it.
For example there is no entity with the
total_export_energy
ortotal_import_energy
. The only energy entity is the inverter daily generation entity.Using the HassOS Addon