Hello Andrei, i am facing the same on My Side, exactly the same as you
descrribed above, have you found any solution for calls disconecting while in
call, by the way th dongle call person can hear a long Tone when call
disconnect while the other person can see call droped without any Tone. i wish
you can help me if you have found any solution for that. waiting your reply &
thanks in advance, mahbabur@gmail.com
Original comment by mahba...@gmail.com
on 18 Feb 2013 at 10:36
By the was i have a linux debian 8 dongles, 4 dongles connected to MotherBoard
and 4 Dongles Connected to USB Card all are hawawi E173 . I Dont Have the
D-link DUB-H7 to connect dongles to it, pls advice.
Original comment by mahba...@gmail.com
on 18 Feb 2013 at 10:41
i was facing the same problem with a self powered Hub and E180 , so far i found
that the problem is with power, USB dongle can't have the enough power
500mAMP,the power adopter for USB hub was though rated as 5 volt and 2AMP , but
wasn't good .Dongle was disconnecting after 2 or 3 seconds .
Bus 001 Device 002: ID 05e3:0608 Genesys Logic, Inc. USB-2.0 4-Port HUB
Bus 001 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub
Bus 001 Device 005: ID 12d1:140c Huawei Technologies Co., Ltd.
Bus 001 Device 004: ID 054c:05ba Sony Corp.
so i replaced the power adopter with Dell PSU (MAx out put 210Watt) .now PSU
provides the 5volt and 2AMP to USB hub.
. so far i can establish a call for 2 mints or so .Dongle dosn't disconnect frequently (though it disconnects ). so my dumb guess is that chan_dongle is OK ,coz this dongle works fine if asterisk is running on PC and dongle is connected directly to pc . but if i use embeded plateform and USB self powered hub then i face problems .
Original comment by alihmd....@gmail.com
on 21 Feb 2013 at 9:43
[deleted comment]
andrei's problem may be related to chan_dongle itself . i also found after few mints test that volts in Power adopter continue to change , sometimes it is providing full 5 volt ,sometimes it's 5.2 volt and sometimes just 4.x volts .
Original comment by alihmd....@gmail.com
on 21 Feb 2013 at 9:50
[deleted comment]
well .the less-diconnection after changing the PSU was becoz i was calling the
Telco IVR for testing :D and they disconnected me after 2 mints while in call,
by calling to other cellphones i came to know that power adopter replacement
actually worked . that frequent disconnect problem is gone now but i faced a
new problem when i used /dev/ttyUSBx interface with chan_dongle . the other
person disconnected the call but dongle status continued to show "dialing" , i
restarted the dongle from CLI but didn't work , i plugged out and in the dongle
then it even didn't show up in 'dongle show devices' , after all i had to
reboot the board , then i used the IMIE and IMSI digits instead of /dev/ttyUSBx
interface and the problems are gone now . though my comments and post are
getting out of the context of the original post by Andrie ,but it may help
others . sorry for hijacking the original post/question/problem.
Original comment by alihmd....@gmail.com
on 21 Feb 2013 at 8:11
Thanks for advice.
I will give it a try to changing power adapter to a brand one - maybe a refurb
branded PC PSU. I will give you details here later.
Thanks,
Andrei
Original comment by andrei.m...@gmail.com
on 22 Feb 2013 at 10:12
[deleted comment]
Andrie , i forgot to mention that i replaced the power adopter with PC PSU ,
,http://www.3sfmedia.net/images//computers/dell-psu_4154.jpg this one. and
powered USB hub with RED(5volt) and Black (GND) wire from a power jack ., plz
first check it with multimeter .
Original comment by alihmd....@gmail.com
on 22 Feb 2013 at 12:01
predictable results
Original comment by bg_...@mail.ru
on 27 Apr 2013 at 3:35