Bugs In specimen resource, when SNOMED code presents, the system, code and display elements are mandatory. The code element is missing at the moment

image

Step to reproduce Check 'full_acceptance_without_nhsack.1.fhir' for an example

Expected behavior the snomed code should be present

bartek-sarul commented 3 years ago

Laboratory might not give us any code for this - only free text. More to that, this requires SNOMED where from current examples laboratory gives not Read2 nor SNOMED hence I'm removing the "system" field

ejudgemeddbase commented 3 years ago

RETEST 1

TEST STEPS TO REPRODUCE ISSUE

Pathology2.txt

I re-ran request pathology_2.edifact and inspected the FHIR load

ACTUAL RESULT

Pathology2FHIR.txt 121Path2

I see that the Code now appears in the Specimen Resource, but no System - as mentioned in an earlier comment.

Retest 1 PASSED