Battery voltage for axiomtek is not read properly #119

Closed dlnorgaard closed 3 years ago

dlnorgaard commented 4 years ago

From Santiago: the battery voltage for axiomtek is not read properly. I notice that the kongo program ‘showlog’ the correct value but there seems to be a problem with NovacProgram not dividing the corresponding reading of the ADC by the correct factor. The reading seems wrong by a factor about 28 (ie gives 336 V instead of 12 V).

dlnorgaard commented 3 years ago

Seems this may not be an issue. Mattias looked back then and found no issue, and Santiago has not brought this up in recent list of issues.