Open Nigusse opened 6 days ago
The investigation has revealed two key issues that have led to the significant differences observed between the HSPF and HSPF2 values for multispeed ASHP. These issues were:
(1) Incorrect value is passed due to order swamp of function arguments in MultiSpeedDXHeatingCoilHSPF2.
(2) The local VAR OATempCompressorOff
was not assigned a value and used its initialized value of 0.
Issue overview
I tested a defect file of a helpdesk ticket 16700 in EnergyPlus Support and confirmed there is a problem how the HSPF is calculated. The HSPF and HSPF2 shouldn't be significantly different. This is a defect.
Details
Some additional details for this issue (if relevant):
Checklist
Add to this list or remove from it as applicable. This is a simple templated set of guidelines.