Blank report name in Output:Table:SummaryReports results in fatal error with no error message identifying the problem #6919

Closed mjwitte closed 8 months ago

mjwitte commented 6 years ago

Issue overview

This object

Output:Table:SummaryReports,
    AnnualBuildingUtilityPerformanceSummary,  !- Report 1 Name
    ZoneHeatingSummaryMonthly,  !- Report 2 Name
    ZoneElectricSummaryMonthly,  !- Report 3 Name
    ZoneCoolingSummaryMonthly,  !- Report 4 Name
    SensibleHeatGainSummary, !- Report 5 Name
    ,!- Report 6 Name
    SpaceGainsMonthly,       !- Report 7 Name
    EnvelopeSummary,         !- Report 8 Name
    ObjectCountSummary,      !- Report 9 Name
    ComponentCostEconomicsSummary,  !- Report 10 Name
    AllSummary;              !- Report 11 Name

results in this error file

Program Version,EnergyPlus, Version 8.9.0-40101eaafd, YMD=2018.08.21 10:40,
   ************* Warning:  Node connection errors not checked - most system input has not been read (see previous warning).
   ************* Fatal error -- final processing.  Program exited before simulations began.  See previous error messages.
   ************* EnergyPlus Warmup Error Summary. During Warmup: 0 Warning; 0 Severe Errors.
   ************* EnergyPlus Sizing Error Summary. During Sizing: 0 Warning; 0 Severe Errors.
   ************* EnergyPlus Terminated--Fatal Error Detected. 0 Warning; 0 Severe Errors; Elapsed Time=00hr 00min  0.14sec

Help desk ticket 13045 has blank meter names in Output:Table:Monthly and Output:Table:Annual

Output:Table:Monthly, Overall HVAC System Energy, !- Name 3, !- Digits After Decimal Cooling:Electricity, !- Variable or Meter 1 Name SumOrAverage, !- Aggregation Type for Variable or Meter 1 , !- Variable or Meter 2 Name SumOrAverage; !- Aggregation Type for Variable or Meter 2

Output:Table:Annual, OUTPUT TABLE 1, !- Name , !- Filter , !- Schedule Name , !- Variable or Meter or EMS Variable or Field 1 Name , !- Aggregation Type for Variable or Meter 1 2, !- Digits After Decimal 1 , !- Variable or Meter or EMS Variable or Field 2 Name , !- Aggregation Type for Variable or Meter 2 2, !- Digits After Decimal 2 , !- Variable or Meter or EMS Variable or Field 3 Name , !- Aggregation Type for Variable or Meter 3 2, !- Digits After Decimal 3 , !- Variable or Meter or EMS Variable or Field 4 Name , !- Aggregation Type for Variable or Meter 4 2, !- Digits After Decimal 4 , !- Variable or Meter or EMS Variable or Field 5 Name , !- Aggregation Type for Variable or Meter 5 2, !- Digits After Decimal 5 , !- Variable or Meter or EMS Variable or Field 6 Name , !- Aggregation Type for Variable or Meter 6 2, !- Digits After Decimal 6 , !- Variable or Meter or EMS Variable or Field 7 Name , !- Aggregation Type for Variable or Meter 7 2, !- Digits After Decimal 7 , !- Variable or Meter or EMS Variable or Field 8 Name , !- Aggregation Type for Variable or Meter 8 2, !- Digits After Decimal 8 , !- Variable or Meter or EMS Variable or Field 9 Name , !- Aggregation Type for Variable or Meter 9 2, !- Digits After Decimal 9 , !- Variable or Meter or EMS Variable or Field 10 Name , !- Aggregation Type for Variable or Meter 10 2, !- Digits After Decimal 10 , !- Variable or Meter or EMS Variable or Field 11 Name , !- Aggregation Type for Variable or Meter 11 2, !- Digits After Decimal 11 , !- Variable or Meter or EMS Variable or Field 12 Name , !- Aggregation Type for Variable or Meter 12 2, !- Digits After Decimal 12 , !- Variable or Meter or EMS Variable or Field 13 Name , !- Aggregation Type for Variable or Meter 13 2, !- Digits After Decimal 13 , !- Variable or Meter or EMS Variable or Field 14 Name , !- Aggregation Type for Variable or Meter 14 2, !- Digits After Decimal 14 , !- Variable or Meter or EMS Variable or Field 15 Name , !- Aggregation Type for Variable or Meter 15 2; !- Digits After Decimal 15 Error file results:

Program Version,EnergyPlus, Version 9.0.0-63db0a5a1f, YMD=2018.08.24 09:46, Warning: Node connection errors not checked - most system input has not been read (see previous warning). Fatal error -- final processing. Program exited before simulations began. See previous error messages. EnergyPlus Warmup Error Summary. During Warmup: 0 Warning; 0 Severe Errors. EnergyPlus Sizing Error Summary. During Sizing: 0 Warning; 0 Severe Errors. ***** EnergyPlus Terminated--Fatal Error Detected. 0 Warning; 0 Severe Errors; Elapsed Time=00hr 00min 11.61sec

Details

Some additional details for this issue (if relevant):

Checklist

Add to this list or remove from it as applicable. This is a simple templated set of guidelines.

Myoldmopar commented 5 years ago

OK, so my changes over in #6983 cause this to be a fatal error. Here's the progression:

Myoldmopar commented 5 years ago

I'm changing this milestone to E+ next and moving on.

jmarrec commented 5 years ago

@Myoldmopar Seems like we should just make it required in IDD. It's a simple IDD change, and the user will know where to go look, no?

mjwitte commented 5 years ago

For Output:Table:SummaryReports, the behavior has been. v8.7, v8.8: ** Severe ** Output:Table:SummaryReports Field[2]="", invalid report name -- will not be reported. Simulation continues to completion. v8.9: unexplained fatal error. v9.0: ** Fatal ** Blank report name in Oputput:Table:SummaryReports. This should have included a transition rule to clean out any blanks so that working files from v8.8 and before would transition successfully. Now these will fail if there are any lurking out there with a blank report field.

Of course we also have a bunch of other old key choice synonyms out there that were never added to transition, so add this to #6601

mjwitte commented 4 years ago

Just retested this, behavior is still the same as noted here. Forgot to deal with the blank field case in #6601, so will make a new pull request to address this in Transition-V8-8-0-to-V8-9-0.

benbrannon-arup commented 2 years ago

Just FYI this seems to still be an issue in 9.6, at least for the Output:Table:Annual. It's easy enough to fix in the text file, but the IDFeditor causes the fatal error. There is also a typo in the error message where Output is spelled 'Oputput'

mjwitte commented 2 years ago

Reopening this issue. Seems we should be able to trap blank unrequired fields and not error out on them, maybe.

JasonGlazer commented 1 year ago

@mjwitte and @Myoldmopar I was thinking about taking on this issue. It seems like this issue started out just trying to make sure a blank report name in Output:Table:SummaryReport occurs. This would be a straightforward fix. But near the end of the conversation, it seems like maybe this is an issue in general about how blank unrequired fields should be treated. That seems very open-ended to try to fix since it probably matters for each field. So which is it?

mjwitte commented 1 year ago

This only applies to blank fields in a few objects that get pre-processed by the input processor. Other blank fields return blank or zero or their default.

@Myoldmopar 's changes in 6983 let blank fields get past the input processor for the pertinent report objects. So, if I'm following correctly, all that's left to do here is to change the fatals added in #6983 to warnings for Output:Table:Monthly, Output:Table:Annual, and Oputput:Table:SummaryReports.

JasonGlazer commented 1 year ago

That is great that it is only those couple of input objects. Thanks @mjwitte

JasonGlazer commented 1 year ago

Do you think they should be Severes or Warnings? I was leaning toward Warnings.

mjwitte commented 1 year ago

Warnings.