EnergyPlus™ is a whole building energy simulation program that engineers, architects, and researchers use to model both energy consumption and water use in buildings.
The EnergyPlus program may crash when the stratified water heat tank inputs are set to autosizing some input parameters such as tank size and height. The issue can be demonstrated by the attached .idf file which is slightly modified from the example file 5ZoneWaterSystems.idf: in the file a stratified water heater replaces the original mixed water heat in the example 5ZoneWaterSystems.idf file.
The temporary workaround is either switching to a mixed water heater (WaterHeater:Mixed), or setting the stratified tank size and height values manually.
Details
Some additional details for this issue (if relevant):
Platform (Operating system, version): All
Version of EnergyPlus 9.3-9.4
Helpdesk ticket number 15592
Checklist
Add to this list or remove from it as applicable. This is a simple templated set of guidelines.
Issue overview
The EnergyPlus program may crash when the stratified water heat tank inputs are set to autosizing some input parameters such as tank size and height. The issue can be demonstrated by the attached .idf file which is slightly modified from the example file 5ZoneWaterSystems.idf: in the file a stratified water heater replaces the original mixed water heat in the example 5ZoneWaterSystems.idf file.
The temporary workaround is either switching to a mixed water heater (WaterHeater:Mixed), or setting the stratified tank size and height values manually.