Open LorenzoBottaccioli opened 2 years ago
Fancoil units do not use setpoints; the coils operate to meet the load. This would require new EMS actuators, or possibly the AirloopHVAC:UnitarySystem could be changed to allow setpoint control when used as zone equipment. @rraustad ?
AirloopHVAC:UnitarySystem should already allow set point control for zone equipment.
Dear All,
I'm trying to control with actuators a
ZoneHVAC:FourPipeFanCoil
since now I was able to control the mass flow rate with the following actuator:I have tried to control the out temperature from the heating coil with the following actuator but I was not able to achieve it:
Any Idea on how I can control the air temperature outlet?
I'm able to do it in an air terminal with
AirTerminal:SingleDuct:ConstantVolume:NoReheat
like the following :By controlling the flowing actuators:
Here you find the details of the
ZoneHVAC:FourPipeFanCoil
Details