OpenStudio is a cross-platform collection of software tools to support whole building energy modeling using EnergyPlus and advanced daylight analysis using Radiance.
While EnergyPlus allows for heat exchange using four nodes (two for the supply side and two for the use side), OpenStudio does not seem to support this setup for WaterHeater:Mixed.
@joseph-robertson can you confirm if this is a current limitation and if it would be possible to add this functionality to OpenStudio to match EnergyPlus capability for WaterHeater:MIxed?