Address PV PDF report template requests to fix #1670. Affects PDF report for Detailed PV, PV Battery, PVWatts, and PVWatts Battery configurations.
Fix PVWatts dc_adj bug.
Weather file used: Weather file string is too long to fit in header. Show data source, e.g., "NSRDB" instead.
Model name and number of user-specified solar modules (when using the user-entered, not database), ditto for inverters: Done. Note that inverter with user-specs does not have a field for inverter name.
Module total capacity in kW, not MW, or both: The report generator script displays module and system capacity in W, kW, or MW depending on system size. Keep this behavior.
Inverter nominal output AC voltage (very important): Done.
Number of strings per inverter (total number of strings divided by number of inverters): This information does not reflect how the model works, and can easily be calculated from info on report, so omitting this request.
Module orientation (portrait or landscape): Not enough space in table.
Albedo: Not enough space in table.
GCR (very important): Done
Distance between rows (bottom of one to bottom of next): Not enough space in table.
Total estimated land area (not just for the modules, but projected onto ground + any additional land specified): Not enough space in table.
Net to grid figure not rounded to nearest 1,000 kWh, but exactly as printed on the bottom of page 3, so they agree: Done
Type of change
Please delete options that are not relevant.
[ ] Bug fix (non-breaking change which fixes an issue)
[X] New feature (non-breaking change which adds functionality)
[ ] Breaking change (fix or feature that would cause existing functionality to not work as expected)
Address PV PDF report template requests to fix #1670. Affects PDF report for Detailed PV, PV Battery, PVWatts, and PVWatts Battery configurations.
Fix PVWatts dc_adj bug.
Weather file used: Weather file string is too long to fit in header. Show data source, e.g., "NSRDB" instead.
Model name and number of user-specified solar modules (when using the user-entered, not database), ditto for inverters: Done. Note that inverter with user-specs does not have a field for inverter name.
Module total capacity in kW, not MW, or both: The report generator script displays module and system capacity in W, kW, or MW depending on system size. Keep this behavior.
Inverter nominal output AC voltage (very important): Done.
Number of strings per inverter (total number of strings divided by number of inverters): This information does not reflect how the model works, and can easily be calculated from info on report, so omitting this request.
Module orientation (portrait or landscape): Not enough space in table.
Albedo: Not enough space in table.
GCR (very important): Done
Distance between rows (bottom of one to bottom of next): Not enough space in table.
Total estimated land area (not just for the modules, but projected onto ground + any additional land specified): Not enough space in table.
Net to grid figure not rounded to nearest 1,000 kWh, but exactly as printed on the bottom of page 3, so they agree: Done
Type of change
Please delete options that are not relevant.
Checklist:
If you have added a new compute module in a SSC pull request related to this one, be sure to check the Process Requirements.