Error is caused by a new attribute/column Peak Load Type to Size On in the Coil Sizing Details table of the EnergyPlus SQL file added in EnergyPlus 9.3.0, which breaks the hard-coded indices in coil_sizing_detail_mapper.rb.
I remapped it using the Coil Sizing Details column headers from OpenStudio 3.4.0 (EnergyPlus 22.1.0) adding all the columns because some were not included in the map. Note, the System Analysis Report didn't render for me with OpenStudio 2.8.1 or 3.4.0.
Error is caused by a new attribute/column
Peak Load Type to Size On
in theCoil Sizing Details
table of the EnergyPlus SQL file added in EnergyPlus 9.3.0, which breaks the hard-coded indices in coil_sizing_detail_mapper.rb.I remapped it using the Coil Sizing Details column headers from OpenStudio 3.4.0 (EnergyPlus 22.1.0) adding all the columns because some were not included in the map. Note, the System Analysis Report didn't render for me with OpenStudio 2.8.1 or 3.4.0.