Test OS-HPXML 1141 #1108

Closed shorowit closed 1 year ago

shorowit commented 1 year ago

Pull Request Description

Test https://github.com/NREL/OpenStudio-HPXML/pull/1441

Checklist

Not all may apply:

shorowit commented 1 year ago

18 project_testing samples (below) show reduced duct area. Indeed none of them have a central heating or cooling system that serves 100% of the load. Results look good. No project_national samples were affected, which either means the number of samples on the CI are not high enough, or that this situation doesn't occur in the baseline runs. Indeed it should be reasonably uncommon.

OSW duct unconditioned area ft2 (delta) cooling system heating system
project_testing-0001.osw -47.68 None Fuel Furnace, 50% Conditioned
project_testing-0007.osw -109.31 Central AC, 60% Conditioned Electric Furnace, 50% Conditioned
project_testing-0009.osw -269.12 None Fuel Furnace, 50% Conditioned
project_testing-0011.osw -56.38 Room AC, 60% Conditioned Fuel Furnace, 80% Conditioned
project_testing-0012.osw -109.25 Central AC, 40% Conditioned Fuel Furnace, 70% Conditioned
project_testing-0019.osw -34.94 None Fuel Furnace, 60% Conditioned
project_testing-0020.osw -1625.09 Central AC, 20% Conditioned None
project_testing-0024.osw -934.16 Room AC, 100% Conditioned Fuel Furnace, 60% Conditioned
project_testing-0026.osw -159.49 Central AC, 20% Conditioned Electric Wall Furnace, 60% Conditioned
project_testing-0027.osw -54.34 Central AC, <10% Conditioned Fuel Furnace, >90% Conditioned
project_testing-0032.osw -170.43 Central AC, 60% Conditioned Electric Furnace, 80% Conditioned
project_testing-0034.osw -168.71 Central AC, 80% Conditioned Fuel Boiler, 80% Conditioned
project_testing-0046.osw -56.38 Central AC, 80% Conditioned None
project_testing-0065.osw -56.38 Room AC, 40% Conditioned Fuel Furnace, 80% Conditioned
project_testing-0073.osw -203.36 Central AC, 80% Conditioned None
project_testing-0081.osw -179.42 Central AC, <10% Conditioned None
project_testing-0092.osw -72.83 Central AC, 80% Conditioned Fuel Furnace, 60% Conditioned
project_testing-0097.osw -541.44 Central AC, 20% Conditioned Fuel Wall/Floor Furnace, 70% Conditioned