NREL / resstock

Highly granular modeling of residential building stocks at national, regional, and local scales using OpenStudio/EnergyPlus.
https://resstock.nrel.gov
Other
103 stars 51 forks source link

NG end uses not correlated #1148

Open ekpresent opened 8 months ago

ekpresent commented 8 months ago

Our results are showing way more homes with LP heating and nonzero NG use than RECS shows. My best guess looking at things is that this is because whether the dryer, cooking, WH, pool heater, and spa heater use NG is all dependent on heating fuel - but independent of each other, whereas in reality a home is much more likely to have multiple of those or none. Not sure what the right fix is but wanted to flag it.

afontani commented 8 months ago

The action would be to look at RECS 2020 and correlate these characteristics. An impact is the number of homes are applicable for upgrades. ResStock LARGEEE is showing more homes applicable compared to RECS.

ekpresent commented 5 months ago

I should have looped back on this back in October. This is still an issue theoretically, but the actual numbers we are seeing once I dig a little further seem to be OK. Could probably close for now, or at least assign very low priority.

This is my revised methodology for doing the comparisons, and my results.

Number of units with primary heating fuel of propane and also some NG usage:

Number of units with primary heating fuel of fuel oil and also some NG usage: