Closed vicgwee closed 2 years ago
Battery state of charge estimation #43 is not accurate, it drops by 60% in the first 3 hours but the last 9% can last it 7 hours.
Solutions:
LIPO_DISCHARGE_CURVE
Data Setup: 380 mAh battery and barometer connected Start time: 1035 hrs
The battery ended at 2445 mV at about 10.5 hrs
Data is here: debugLog00006.csv
Similar findings here: debugLog00007.csv
Will try implementing the voltage offset first
Battery state of charge estimation #43 is not accurate, it drops by 60% in the first 3 hours but the last 9% can last it 7 hours.
Solutions:
LIPO_DISCHARGE_CURVE
based on these experimental values.Data Setup: 380 mAh battery and barometer connected Start time: 1035 hrs
The battery ended at 2445 mV at about 10.5 hrs
Data is here: debugLog00006.csv