Currently, the constant flow rate option results in only constantFlowScale and flowRateError being displayed at each timestep. Nek5000 displays the timestep, direction, delta_flow, current_flow, and the prescribed flow_rate in the following fashion:
1 Volflow Z 1.9000E+01 1.4217E-02 3.4874E-06 7.8539E-01 7.8540E-01
These values are important for understanding the state of the unmodified solution and the flow rate correction.
Currently, the constant flow rate option results in only
constantFlowScale
andflowRateError
being displayed at each timestep. Nek5000 displays the timestep, direction,delta_flow
,current_flow
, and the prescribedflow_rate
in the following fashion:These values are important for understanding the state of the unmodified solution and the flow rate correction.
cc'ing @fischer1