NetAppDocs / ontap-systems-switches

https://docs.netapp.com/us-en/ontap-systems-switches/
3 stars 8 forks source link

Shouldn't this page have a step on disabling cluster LIF auto-revert? #133

Open farkeytron opened 9 months ago

farkeytron commented 9 months ago

Page URL

https://docs.netapp.com/us-en/ontap-systems-switches/switch-cisco-3232c/upgrade-3232c-storage-switches.html

Page title

Upgrade a Cisco Nexus 3232C storage switch

Summary

As far as I know, if the customer upgrades the switches without disabling LIF auto-revert, ONTAP will move the LIFs back when the switch reboots and comes back online.

If the two cluster switch firmware and/or RCF files are not compatible, and the ISLs aren't passing traffic, the cluster could experience an outage.

Auto-revert should be disabled at the beginning so the LIFs only migrate, but don't revert, until both switches are upgraded.

Did anyone vet this doc page before it was published?

Public issues must not contain sensitive information

netapp-yvonneo commented 8 months ago

@farkeytron thanks for highlighting this issue. We'll review this feedback and update the documentation accordingly.