NetAppDocs / ontap-systems-switches

https://docs.netapp.com/us-en/ontap-systems-switches/
3 stars 9 forks source link

Wrong commands listed for BES-53248 - not EFOS CLI #135

Closed andris-ntap closed 1 year ago

andris-ntap commented 1 year ago

Page URL

https://docs.netapp.com/us-en/ontap-systems-switches/switch-bes-53248/migrate-cn1610.html

Page title

Migrate CN1610 cluster switches to BES-53248 cluster switches

Summary

Step 12. Confirm the switch port connections are healthy from switch cs2’s perspective using the commands:

cs2# show interface brief cs2# show cdp neighbors

Those are not valid EFOS commands. Change them to:

cs2# show port all cs2# show isdp neighbors

Same changes for the CLI commands listed in Step 19: Step 19. Confirm the switch port connections are healthy from switch cs1’s perspective using the commands:

Public issues must not contain sensitive information

netapp-yvonneo commented 1 year ago

@andris-ntap thanks I'll make those updates today.

netapp-yvonneo commented 1 year ago

@andris-ntap the updated commands are available here: https://docs.netapp.com/us-en/ontap-systems-switches/switch-bes-53248/migrate-cn1610.html#step-2-configure-ports-and-cabling. Closing this issue.