Closed andris-ntap closed 1 year ago
@andris-ntap thanks I'll make those updates today.
@andris-ntap the updated commands are available here: https://docs.netapp.com/us-en/ontap-systems-switches/switch-bes-53248/migrate-cn1610.html#step-2-configure-ports-and-cabling. Closing this issue.
Page URL
https://docs.netapp.com/us-en/ontap-systems-switches/switch-bes-53248/migrate-cn1610.html
Page title
Migrate CN1610 cluster switches to BES-53248 cluster switches
Summary
Step 12. Confirm the switch port connections are healthy from switch cs2’s perspective using the commands:
cs2# show interface brief cs2# show cdp neighbors
Those are not valid EFOS commands. Change them to:
cs2# show port all cs2# show isdp neighbors
Same changes for the CLI commands listed in Step 19: Step 19. Confirm the switch port connections are healthy from switch cs1’s perspective using the commands: