NetAppDocs / ontap-systems-switches

https://docs.netapp.com/us-en/ontap-systems-switches/
3 stars 9 forks source link

steps 6-10 should be change #161

Closed netappmf closed 8 months ago

netappmf commented 9 months ago

Page URL

https://docs.netapp.com/us-en/ontap-systems-switches/switch-bes-53248/migrate-to-2n-switched.html

Page title

Migrate to a switched NetApp cluster environment

Summary

step 6 of this guide says to disable the auto-revert

cluster1::> network interface modify -vserver Cluster -lif -auto-revert false

step 9 says to enable the ports on the clusterswitch step 10 says to check if all the cluster ports are back home

However since we disable auto-revert they won't return home automatically. So either auto-revert should be enabled or there is an extra step between 9 and 10 needed to manually revert the cluster lifs.

Public issues must not contain sensitive information

netapp-yvonneo commented 9 months ago

@netappmf thanks for your feedback. We'll review the documentation and update accordingly.

netapp-yvonneo commented 8 months ago

@netappmf the document has been updated accordingly, see here: https://docs.netapp.com/us-en/ontap-systems-switches/switch-bes-53248/migrate-to-2n-switched.html