NetAppDocs / ontap-systems-switches

https://docs.netapp.com/us-en/ontap-systems-switches/
3 stars 8 forks source link

warning for usage of using 10G/25G combinations #163

Closed netappmf closed 3 months ago

netappmf commented 4 months ago

Page URL

https://docs.netapp.com/us-en/ontap-systems-switches/switch-bes-53248/migrate-to-2n-switched.html

Page title

Migrate to a switched NetApp cluster environment

Summary

Hello Support

I think it might be a good idea to add a warning or Info about the 10G/25G ports when using them with both port speeds. We've seen this at cluster migrations from a old (10G) Cluster to a new (25G) cluster. The RCF has a small Note that says

However it doesn't say that if those ports are connected together (for example port1,2 = 10G port 3,4 =25G), all ports will go down what will cause a unhealthy cluster. So to prevent this a warning for those combinations would be great

Thanks and Regards Marco

Public issues must not contain sensitive information

netapp-yvonneo commented 4 months ago

@netappmf thanks for your feedback. We'll review the documentation and update accordingly.

netapp-yvonneo commented 3 months ago

@netappmf the document has been updated accordingly, see here: https://docs.netapp.com/us-en/ontap-systems-switches/switch-bes-53248/migrate-to-2n-switched.html