To prevent out of quruom issues extra warnings need to be displayed #178

Closed emile-bodin closed 7 months ago

emile-bodin commented 7 months ago

Page URL

https://docs.netapp.com/us-en/ontap-systems-switches/switch-cisco-9336c-fx2/migrate-to-9336-cluster.html

Page title

Migrate from an older Cisco switch to a Cisco Nexus 9336C-FX2 cluster switch

Summary

as part if ONTAP's full mesh requirement during operations like this it is required to follow this plan exactly.

Some steps need to be highlighted as important and not to be skipped/ignored. Failing to do so can cause data access disruptions

step 4 - mandatory step 5 - make sure that the ports are "shut" as a group (just like in the command) and not 1 by 1 step 12 - make sure that the ports are "shut" as a group (just like in the command) and not 1 by 1. Do not manually migrate any cluster lifs When this step is done all interfaces force migrate to CS2 automatically. Ensuring full mesh connections.

Public issues must not contain sensitive information

netapp-yvonneo commented 7 months ago

@emile-bodin thanks for your feedback. We'll review your request and update the documentation accordingly.

netapp-yvonneo commented 7 months ago

@emile-bodin thanks for your feedback. The procedure had been updated for the steps mentioned. Closing this issue.