NetAppDocs / ontap-systems-switches

https://docs.netapp.com/us-en/ontap-systems-switches/
3 stars 8 forks source link

queries for current steps of Install RCF #196

Open zhuolin-shen opened 4 days ago

zhuolin-shen commented 4 days ago

Page URL

https://docs.netapp.com/us-en/ontap-systems-switches/switch-cisco-3132q-v/install-rcf-3132q-v.html

Page title

Install the Reference Configuration File (RCF)

Summary

Screenshot 2024-07-01 121043 The reason why the same RCF needs to be applied twice is unclear, but is it necessary? Since we have not performed a reboot after applying the RCF for the second time, I believe we have not confirmed whether the configuration applied with the second RCF is functioning correctly. Is a reboot not necessary?

Public issues must not contain sensitive information

netapp-yvonneo commented 4 days ago

@zhuolin-shen thanks for your feedback. We'll review the docs and update them accordingly.