Need to add a command when setting BMC IP information #68

Closed Woodrow17 closed 11 months ago

Woodrow17 commented 1 year ago

Page URL

https://docs.netapp.com/us-en/storagegrid-116/sg6000/replacing-sg6000-cn-controller.html

Page title

Replace SG6000-CN controller

Summary

Please add the following command for Step 7 section a.

run-host-command ipmitool lan set 1 ipsrc static

The command list should look like this...

run-host-command ipmitool lan set 1 ipsrc static

run-host-command ipmitool lan set 1 ipaddr Appliance_IP

run-host-command ipmitool lan set 1 netmask Netmask_IP

run-host-command ipmitool lan set 1 defgw ipaddr Default_gateway

Public issues must not contain sensitive information

netapp-maireadn commented 1 year ago

Thanks @Woodrow17 for your suggestion. I will liaise with the StorageGrid writing team and work on this as soon as possible.

netapp-pcarriga commented 11 months ago

Hi @Woodrow17, we are not planning to make this update to version 11.6 of the documentation site but we will address this issue in future versions. Thanks again for bringing this issue to our attention and for understanding.

netapp-pcarriga commented 10 months ago

Hi @Woodrow17, post closure of this issue, this documentation request was published in the StorageGRID 11.6 documentation: https://docs.netapp.com/us-en/storagegrid-116/sg6000/replacing-sg6000-cn-controller.html