Niilo007 / Stationeers-Research

Documentation and MIPS code for the game "Stationeers"
0 stars 0 forks source link

Heat exchanger rate calculations #29

Open Niilo007 opened 11 months ago

Niilo007 commented 11 months ago
Niilo007 commented 11 months ago

Observation 1 on the same system: Large ~10kJ small ~1.1kJ

Niilo007 commented 11 months ago

In theory: pressures above 1 atm should not have an effect formula for convection =(100area(lefttemp-righttemp))

Niilo007 commented 10 months ago

StructureHeatExchangeLiquidtoGas Surface area: 7.245596 Exchange Area: Volume: 100

StructureHeatExchangerGastoGas Surface area: 7.245596 Exchange Area: Volume: 100

StructureHeatExchangerLiquidtoLiquid Surface area: 7.245104 Exchange Area: Volume: 100

StructureLargeDirectHeatExchangeGastoGas Surface area: 16.00713 Exchange Area: 8

StructureLargeDirectHeatExchangeGastoLiquid Surface area: 16.00713 Exchange Area: 8

StructureLargeDirectHeatExchangeLiquidtoLiquid Surface area: 16.00704 Exchange Area: 8

StructurePassthroughHeatExchangerGasToGas Surface area: 7.344498 Exchange Area:

StructurePassthroughHeatExchangerGasToLiquid Surface area: 7.344277 Exchange Area:

StructurePassthroughHeatExchangerLiquidToLiquid Surface area: 7.343492 Exchange Area:

StructureSmallDirectHeatExchangeGastoGas Surface area: 3.921878 Exchange Area: 1

StructureSmallDirectHeatExchangeLiquidtoGas Surface area: 3.921877 Exchange Area: 1

StructureSmallDirectHeatExchangeLiquidtoLiquid Surface area: 3.921877 Exchange Area: 1