Problem
The problem is that we want to see the average temps for the segments. Right now we only send overall average pack temp and individual cell temps, but we want to compute and send average temp for segments as well.
List any ideas of possible solutions
When we calculate individual cell temps calculate the average chip temps as well and then calculate the average segment temp via the two average chip temps per segment.
Is it a hardware-related issue or purely software? i.e. firmware vs software?
Software
Estimated time commitment/scope
idk prob very quick
Problem The problem is that we want to see the average temps for the segments. Right now we only send overall average pack temp and individual cell temps, but we want to compute and send average temp for segments as well.
List any ideas of possible solutions When we calculate individual cell temps calculate the average chip temps as well and then calculate the average segment temp via the two average chip temps per segment.
Is it a hardware-related issue or purely software? i.e. firmware vs software? Software
Estimated time commitment/scope idk prob very quick
Anything else that might be relevant? negative