Well Alloc Plot: Consider flipping the sign or Axis for injectors #1201

Open JacobStoren opened 7 years ago

JacobStoren commented 7 years ago

As they have negative flow, and to make the plots more like well logs

hhgs commented 7 years ago

Production logging of injectors typically plot injection rate with negative flow.