ORNL-AMO / AMO-Tools-Desktop

AMO-Tools-Desktop is an energy efficiency calculation application for use with industrial equipment such as pumps, furnaces, fans, and motors, as well as for industrial systems such as steam. Currently in beta.
Other
39 stars 22 forks source link

PHAST- Add a new material -Liquid- Unit #1118

Closed AshaShibu closed 6 years ago

AshaShibu commented 6 years ago

The unit of Latent Heat of Vaporization should be changed to Btu/lb-F . Check unit conversion as well

koay9f commented 6 years ago

image

Latent Heat of Vaporization is not converting correctly. I entered "32" for each field in imperial. Latent Heat ... should = 133.977...

koay9f commented 6 years ago

Opps. okay, so the conversion is now correct (and it should be 32 Btu/lb, 74.432 kJ/kg), but the unit label is not. It should be Btu/lb and kJ/kg

Again, JUST THE LABEL is wrong. My fault.

AshaShibu commented 6 years ago

It is now using the conversion for Btu/lb-F to kJ/kgC. It needs to be the conversion for Btu/lb to kJ/kg The label is right but the conversion is now wrong