Closed AshaShibu closed 6 years ago
Latent Heat of Vaporization is not converting correctly. I entered "32" for each field in imperial. Latent Heat ... should = 133.977...
Opps. okay, so the conversion is now correct (and it should be 32 Btu/lb, 74.432 kJ/kg), but the unit label is not. It should be Btu/lb and kJ/kg
Again, JUST THE LABEL is wrong. My fault.
It is now using the conversion for Btu/lb-F to kJ/kgC. It needs to be the conversion for Btu/lb to kJ/kg The label is right but the conversion is now wrong
The unit of Latent Heat of Vaporization should be changed to Btu/lb-F . Check unit conversion as well