Open-Bionics / Brunel

Design files relating to the Brunel Robotic Hand
30 stars 21 forks source link

Ligament cover doesn't clamp ligament #15

Closed JonathanRaines closed 8 years ago

JonathanRaines commented 8 years ago

It fits well but the castellations aren't tall enough to reach the ligament

JonathanRaines commented 8 years ago

Height of castellations increased to interfere with the ligament by 0.5 mm