Cables are being folded flat between back cover and PCB #79

Open JonathanRaines opened 7 years ago

JonathanRaines commented 7 years ago

The last fold before the flat flex connects to the board is being squashed flat between the back cover and the motors.

JonathanRaines commented 7 years ago

The situation has been improved but there is still a 'fold' in the flatflex. The cables haven't failed and there should be no cyclical failure to worry about. However, it would be preferable to remove it completely.

JonathanRaines commented 7 years ago

9cca2b948842dc01da25d02f773a131241e70f4b

Changed the cable tidy slot to concertina the cable. It turns out only the proximal two slots were needed.

JonathanRaines commented 7 years ago

Tested with the back cover. The cables are no longer folded flat; they even have about 6 mm clearance.