Open-Systems-Pharmacology / MoBi

MoBi® is a software tool for multiscale physiological modeling and simulation
Other
29 stars 9 forks source link

Initial conditions from modules are not applied #1463

Open PavelBal opened 1 month ago

PavelBal commented 1 month ago

ic-not-applied.zip

The simulation "test" is created from a PK-Sim module and an Extension module FullStructure_. In addition, Expression profiles are selected

image

The IC BB has an entry for molecule GABRG2 in Organism|VenousBlood|Plasma with the value set to 1 µmol:

image

This value is not applied in the simulation:

image

PavelBal commented 1 month ago

Upd: the value is applied if the Expression Profile is removed. So obviously, values from the expression profile are applied after the IC BB.

PavelBal commented 1 month ago

The expected behavior (also see - https://github.com/Open-Systems-Pharmacology/OSMOSES/issues/60)

FIRST information from Expression Profile and Individual, THEN PV BB and IC BB

Currently, the behavior is inconsistent.