Cannot drag-and-drop a custom parameter from the "Possible referenced objects" list #1530

Closed PavelBal closed 3 days ago

PavelBal commented 2 weeks ago

Lysosome_2.zip

In the attached project:

I have created an extension module "Lysosome". In this module, I have defined a new "MoleculeProperties" parameter Partition coefficient (water/lysosome) located in MoleculeProperties|Partition coefficient (water/lysosome):

image

Now in the same module, under Organism|Bone|Lysosome|MoleculeProperties, I want to use this parameter in a formula. It so correctly listed in the Lysosome - Organism|Midazolam tree in the "Possible referenced objects" view, but I cannot drag-and-drop it in the aliases - frame. This works for other parameters.

image

PavelBal commented 2 weeks ago

And this used to work.