Open-Systems-Pharmacology / OSP-based-publications-and-content

Publications of all kind based on the Open Systems Pharmacology Suite
15 stars 2 forks source link

Poster at PAGE 2023: Comparison of monoclonal antibody disposition predictions between different PBPK platforms #498

Open Yuri05 opened 1 year ago

Yuri05 commented 1 year ago

Pieter-Jan De Sutter, Elke Gasthuys, An Vermeulen

https://www.page-meeting.org/default.asp?abstract=10283

Objectives: Most monoclonal antibodies (mAbs) target soluble- or membrane bound antigens located outside the vasculature. While these concentrations at the effect-site might be better predictors for efficacy and safety, they are generally inaccessible for clinical PK/PD sampling. One way to predict tissue concentrations is through physiologically based pharmacokinetic modelling (PBPK). Several PBPK modelling platforms have a specific module for the prediction of mAb disposition, but whether the models are of comparable accuracy has not been independently assessed. The primary aims of this work were to compare predicted plasma and tissue concentrations of mAbs between three PBPK modelling platforms and to evaluate the accuracy of predictions against observed data.

Methods: PBPK simulations were done in Simcyp® (v21), PK-Sim® (v11) and GastroPlus (v9.8.2) for three different mAbs: intravenous IgG (IgGIV), adalimumab and infliximab. For IgGIV, compound parameters (i.e. molecular weight and FcRn affinity) of endogenous IgG were used as specified in the simulators, while for adalimumab and infliximab, independent in-vitro data were used. All simulations were done for a standard virtual male healthy volunteer (height: 176.6 cm, body weight: 80.7 kg). Concentration-time profiles in plasma and comparable tissues defined in all platforms (adipose, brain, heart, kidney, liver, lung, muscle, skin and spleen) were used as primary outputs. Area under the curve (AUC) and half-life (t½) were calculated with the PKNCA R package. Parameters were quantitively compared between platforms using the percent coefficient of variation (%CV). Agreement between model outcomes and observed literature data was expressed as fold errors (FE) for individual observations and absolute average fold errors (AAFEs) for multiple observations. The proposed antibody distribution coefficients (ABC, i.e. the tissue/plasma concentration ratios) by Shah and Betts (total concentrations) and Rafidi et al. (interstitial fluid (ISF) concentrations) were used for the accuracy assessment of tissue distribution. To investigate the accuracy of predictions of mAb plasma kinetics, we compared model predictions with published observed data originating from five different clinical studies investigating the PK of adalimumab [6,7] and infliximab [8–10] at different intravenous doses.

Results: Differences in plasma kinetics of IgGIV between platforms were minimal for a dose of 1 mg/kg (9%CV for AUC0-672h, 5%CV for t½). The associated total tissue profiles differed significantly between the platforms: of the 9 comparable tissues, only 4 had a %CV on AUC0-672h below 50%: adipose (27%CV), brain (11%CV), heart (15%CV) and muscle (15%CV). Predicted ABCs for total tissue concentrations were within twofold of observed values except for brain (FEs: 8.12, 6.40 and 9.49 in Simcyp, PK-Sim and GastroPlus, respectively), lung (FE: 2.85 in PK-Sim), skin (FE: 0.36 in GastroPlus) and spleen tissue (FE: 2.44 in PK-Sim). For AUC0-672h values calculated from ISF tissue concentrations, only heart and lung values varied less than 50%CV between platforms (12 and 42 %CV, respectively). ABCs based on ISF concentration were within twofold except for adipose (FE: 3.65, Simcyp), brain (FE: <0.01 in Simcyp, FE: 2.94 in PK-Sim), heart (FE: 0.34 in Simcyp and GastroPlus, FE: 0.23 in PK-Sim), muscle (FE: 0.29 in GastroPlus) and skin (FE: 0.25 in GastroPlus). The overall accuracy of the plasma profiles of adalimumab was similar across platforms; (AAFE of 1.36, 1.40 and 1.55 in Simcyp, PK-Sim and GastroPlus, respectively). For infliximab, the AAFEs were higher but also similar across platforms; 1.95 for Simcyp, 1.96 for PK-Sim and 2.28 for GastroPlus. Predicted AUCinf and t½ of both mAbs were higher than observed values. Incorporation of target-mediated-drug disposition did not resolve the overprediction of t½.

Conclusions: These results show that plasma predictions of mAbs are similar across the investigated PBPK platforms but tissue predictions vary considerably. When using PBPK to assess effect-site concentrations in tissues, the model verification procedure should not be confined to plasma only but also include an accuracy assessment on the tissue(s) of interest.