vfbl commented 3 years ago

Openhantek 30.10.2020_e7e0ec7b built on 64bit Debian with DSO-2090 USB.

No triggering happened after first shot when set to EXT or EXT/10 with EXT connected together with CH1 to 2Vpp 1K test outlet.

EXT and EXT/10 work as expected on stock win10 and XP hantek exec. BTW, the stock has an extra trigger setting of ALT (alternating between CHI and CH2).

Same issue seen on pulseview over sigrok.

vfbl commented 3 years ago

It turns out to be same as #285. I got some triggering on EXT by setting specification.specialTriggerChannels to -1. OK for now, Other minus settings beyond -3 seem working too. However I cannot really tell which is EXT/10 until I have an adjustable trigger source. It is likely a modelling issue as sigrok has the same problem.

vfbl commented 3 years ago

Close duplicate.