OpenModelica / OpenModelica

OpenModelica is an open-source Modelica-based modeling and simulation environment intended for industrial and academic usage.
https://openmodelica.org
Other
780 stars 297 forks source link

Model Buildings.Fluid.Chillers.Validation.Carnot_TEva_reverseFlow fails verification #12691

Open AndreaBartolini opened 3 days ago

AndreaBartolini commented 3 days ago

The following variables of the model Buildings.Fluid.Chillers.Validation.Carnot_TEva_reverseFlow fail the verification vs the Dymola reference file:

both of them are calculated by using the Media model and the actualStream() operator (flow reversal is allowed).

The verification fails in zero-flow condition, where the behavior of the actualStream() operator is tool-dependent: image

casella commented 3 days ago

@mwetter usual story: should we exclude temperature signals that are unreliable in some time intervals?