The same thing happened for me with the MCOHome MH-DT411 Dimmer Switch. I fixed it for this device by setting it's option "12: Reporting interval for dimming level" to 0. This made the device's behavior better suited to openzwave's characteristics.
Does your device have a similar option?
I have looked up the manual for your device, but didn't find a setting like on mine. What you could try however is set option 8 to 0. My guess is that should avoid sending intermediate updates, because the dimmer goes from its current value to the new value instantly.
Parameter 8, Parameter Size 1. Dimming Duration. The parameter defines how long it takes to dim to the desired level. Note! Only Multilevel Switch Command Class is affected by this parameter. VALUE DESCRIPTION 0 Disabled 1 - 127 Duration in seconds (1 - 127 seconds. Default is 1) 128 - 255 Duration in minutes (1 - 127 minutes)
When manually dimming a Heatit Z-dim dimmer using the dimming wheel z-wave goes in to a constant loop. Where it seems to me like target value is never met.